=Overview=
=Overview=


Discoveries about the brain have implications for fields ranging from Business, Law, Psychology, and Education. The interest of measuring metabolic changes via MRS techniques and combining that information with functional MRI measurements continues to grow. CNI continues to support the research of its user community by providing state-of-the art data acquisition and state-of-the-art data management and analysis capabilities for in-vivo spectroscopy. Through collaborative efforts the special interest spectroscopy group at CNI has enabled education, participated in experimental design, and guided analyses and interpretation of results.
'''Discoveries about the brain have implications for fields ranging from Business, Law, Psychology, and Education. The interest of measuring metabolic changes via MRS techniques and combining that information with functional MRI measurements continues to grow. CNI continues to support the research of its user community by providing state-of-the art data acquisition and state-of-the-art data management and analysis capabilities for in-vivo spectroscopy. Through collaborative efforts the special interest spectroscopy group at CNI has enabled education, participated in experimental design, and guided analyses and interpretation of results.'''


'''Examples of studies at CNI using in-vivo spectroscopy techniques include characterization of biomarkers following transcranial magnetic stimulation, and metabolite characterization for conditions such as substance addiction, pain, depression, and various forms of dementia. These studies illustrate integrated data acquisition and data processing tools accessible to the CNI user community which simplify the use and sharing of spectroscopy results in neuroimaging applications.'''


An excellent spectroscopy resource website is https://mrshub.org/  
'''[https://doi.org/10.1093/cercor/bhz332 Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability] DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332'''
The MRSHub is a curated collection of resources for the analysis of magnetic resonance spectroscopy data. It is maintained by the Committee for MRS Code and Data Sharing of the MR Spectroscopy Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM).


=Data Acquisition and Processing Tools=
'''The CNI continues to support the research of its user community by developing and incorporating for general use new data acquisition and data analysis capabilities.'''


==Spectroscopy Sequences==
'''[https://doi.org/10.1002/mrm.26691 GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence] Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691'''
 
'''[https://doi.org/10.1016/j.neuroimage.2021.118430 Frequency drift in MR spectroscopy at 3T] Hui et al. Frequency drift in MR spectroscopy at 3T https://doi.org/10.1016/j.neuroimage.2021.118430'''
 
=Spectroscopy Websites and Literature=
 
 
'''Websites:'''


The Stanford CNI effort has become a best practice through a community effort with spectroscopy expertise from CNI staff, MRI scientists, and an expanding user community. Current spectroscopy sequences include methods both for edited GABA (gamma-Aminobutyric acid) specific data acquisition (MEGA-PRESS [1] and IM-SPECIAL [3]), and for multi-metabolite data acquisition (Optimized-PRESS [4], [5], [6]). Additional sequences such as semi-LASER [9], [10], [11], [12], [13] are being evaluated and added as newer data acquisition methods.
'''An excellent spectroscopy resource website is https://mrshub.org/ '''
'''The MRSHub is a curated collection of resources for the analysis of magnetic resonance spectroscopy data. It is maintained by the Committee for MRS Code and Data Sharing of the MR Spectroscopy Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM).'''


To analyze the data from MEGA-PRESS experiments Gannet can be used. It is a batch-analysis tool for GABA-edited MRS data. The Gannet code and instruction manual can be downloaded from here http://www.gabamrs.com/


{| class="wikitable"
|-
! Spectroscopy Sequence
! Measured Metabolites
! Analysis Methods
|-
|MEGA-PRESS [1]
|GABA+, Glx(Glutamate, Glutmine)
|Gannet [2]
|-
|IM-SPECIAL [3]
|GABA, Glu(Glutamate), Glx(Glutamate, Glutamine)
|Sequence specific Matlab code
|-
|Optimized-PRESS [4], [5], [6]
|All metabolites
|Sequence specific Matlab code, LCModel fitting [7]
|-
|semi-LASER [9], [10], [11], [12], [13]
|All metabolites
|Sequence specific Matlab code, LCModel fitting [7]
|}


'''Books:'''


===References===
[http://onlinelibrary.wiley.com/book/10.1002/9780470512968;jsessionid=5537E205EAAA89060F0EE654DB7CAD21.f02t01 In Vivo NMR Spectroscopy, 2nd Edition, Author: Robin de Graaf, Wiley Online Library]


[1] Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression, NMR Biomed. 11:266–272  https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291099-1492%28199810%2911%3A6%3C266%3A%3AAID-NBM530%3E3.0.CO%3B2-J
'''The recently updated 3rd edition:    [https://onlinelibrary.wiley.com/doi/book/10.1002/9781119382461 In Vivo NMR Spectroscopy, 3rd Edition, Author: Robin de Graaf, Wiley Online Library]'''


[2] Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris, Peter B. Barker, and C. John Evans (2014) Gannet: A Batch-Processing Tool for the Quantitative Analysis of Gamma-Aminobutyric Acid–Edited MR Spectroscopy Spectra, Journal of Magnetic Resonance Imaging 40:1445–1452  https://doi.org/10.1002/jmri.24478
The 2014 book [http://www.sciencedirect.com/science/book/9780124016880 Magnetic Resonance Spectroscopy - Tools for Neuroscience Research and Emerging Clinical Applications]


[3] Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47  https://doi.org/10.1002/mrm.26691


[4] Webb PG, Sailasuta N, Kohler SJ, Raidy T, Moats RA, Hurd R (1994) Automated single voxel proton MRS: technical development and multisite verification, Magnetic Resonance in Medicine 31(4):365-373  https://doi.org/10.1002/mrm.1910310404
'''Papers:'''


[5] Bodenhausen G, Freeman R, Turner DL (1977) Suppression of artifacts in two dimensional J spectroscopy, Journal of Magnetic Resonance Imaging 27:511-514 https://doi.org/10.1016/0022-2364(77)90016-6
'''A very comprehensive collection of MRS papers have been published in 2021 in a special issue of NMR in Biomedicine - Advanced methodology for in vivo magnetic resonance spectroscopy - https://doi.org/10.1002/nbm.4504'''


[6] Tran TK, Vigneron DB, Sailasuta N, Tropp J, Le Roux P, Kurhanewicz J, Nelson S, Hurd R (2000) Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer, Magnetic Resonance in Medicine 43(1):23-33. https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291522-2594%28200001%2943%3A1%3C23%3A%3AAID-MRM4%3E3.0.CO%3B2-E
'''Key points abstracted from the Editorial page of this special issue are summarized here and the most relevant papers to the CNI spectroscopy tools are in bold type:'''


[7] Provencher SW (2001) Automatic quantitation of localized in vivo1H spectra with LCModel, NMR in Biomedicine 14(4):260-264  https://doi.org/10.1002/nbm.698
"For this Special Issue, these 13 topics of advanced methodology in clinical and pre-clinical MRS have been reviewed by multi-institutional groups of authors, and a consensus overview of the most relevant facts and recommendations has been assembled for each of them. They now appear along with proffered review papers from single or smaller groups of authors and proffered research papers with a broad range of topics covering latest research results."


[8] Young Woo Park, Dinesh K. Deelchand, James M. Joers, Brian Hanna, Adam Berrington, Joseph S. Gillen, Kejal Kantarci, Brian J. Soher, Peter B. Barker, HyunWook Park, Gulin Oz, Christophe Lenglet (2018) AutoVOI: real-time automatic prescription of volume-of-interest for single voxel spectroscopy, Magn. Reson. Med. 80:1787–1798  https://doi.org/10.1002/mrm.27203
"The consensus articles that lay out the current state of the art and present recommendations for use in terms of several aspects of advanced MRS were written by teams of prime experts in these fields, where the teams had been instructed to self-organize under consideration of the width of the field and respecting geographic and gender aspects. However, limiting the number of authors to a size that allows productive interchange, it was not possible to include all potential expert authors as based on their publication records. Thus, it was decided for many of the papers to include a larger group of experts as a collaborator group to receive input from and to cross-check and support the experts' recommendations. None of these papers that include “experts' consensus recommendations” in their titles are to be considered as typical white papers where traditionally detailed advice on exact measurement protocols and parameters is given. This had not been our intention because the topics covered are of an advanced nature and hence inherently still touch many work-in-progress frontiers. Furthermore, all topics covered still present challenges in terms of identifying overall optimal methods as approved by the community as a whole. In contrast, the recommendations in these papers were arrived at as a consensus opinion among the specific group of experts without claiming validity for the whole community, and also with the possibility to vary the weight of advice from hints to more strongly encouraged recommendations."


[9] Scheenen TWJ, Klomp DWJ, Wijnen JP, Heerschap A. (2018) Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses, Magn. Reson. Med. 59(1):1-6  https://doi.org/10.1002/mrm.21302
"The experts' consensus papers are targeted primarily at two types of readers: on one hand, the non-MRS-specialized MR physicist or high-end user (eg a clinician or neuroscientist) commissioned with the task of implementing state-of-the-art MRS methods for a specific research or clinical target that go beyond the vendor-provided MRS techniques; on the other hand, MRS specialists who try to grasp the background and current advances in topics with which they are not intimately familiar and to provide starting points to them when they consider incorporating them in their research or technical developments."


[10] Oz G, Tkac I. (2011) Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem, Magn. Reson. Med. 65(4):901-910  https://doi.org/10.1002/mrm.22708
The 13 topics for the experts' consensus recommendation papers include two general papers followed by articles on specific topics in advanced MRS grouped in three fields of research.


[11] Martin Wilson, Ovidiu Andronesi, Peter B. Barker, Robert Bartha, Alberto Bizzi, Patrick J. Bolan, Kevin M. Brindle, In-Young Choi, Cristina Cudalbu, Ulrike Dydak, Uzay E. Emir, Ramon G. Gonzalez, Stephan Gruber, Rolf Gruetter, Rakesh K. Gupta, Arend Heerschap, Anke Henning,Hoby P. Hetherington, Petra S. Huppi, Ralph E. Hurd, Kejal Kantarci, Risto A Kauppinen, Dennis W. J. Klomp, Roland Kreis, Marijn J. Kruiskamp, Martin O. Leach, Alexander P. Lin, Peter R. Luijten, Malgorzata Marjanska, Andrew A. Maudsley, Dieter J. Meyerhoff, Carolyn E. Mountford, Paul G. Mullins, James B. Murdoch, Sarah J. Nelson, Ralph Noeske, Gulin Oz, Julie W. Pan, Andrew C. Peet, Harish Poptani, Stefan Posse, Eva-Maria Ratai, Nouha Salibi, Tom W. J. Scheenen, Ian C. P. Smith, Brian J. Soher, Ivan Tkac, Daniel B. Vigneron, Franklyn A. Howe (2019) Methodological consensus on clinical proton MRS of the brain:Review and recommendations, Magn. Reson. Med. 82:527–550 https://doi.org/10.1002/mrm.27742
'''*Two papers on the general background of methodology and publishing in MRS.'''
'''**Terminology and concepts in MRS Kreis R, Boer V, Choi IY, et al. Terminology and concepts for the characterization of in vivo MR spectroscopy methods and MR spectra: background and experts' consensus recommendations. NMR Biomed. 2020;e4347.  https://doi.org/10.1002/nbm.4347 The first article of the special issue has the broad scope of presenting the basic framework of concepts and terminology in the field of in vivo MRS, which will hopefully help to standardize the language used and thus prevent misunderstandings in future publications in the field. It also contains suggestions for the use of abbreviations and provides references to the origin of concepts, methods and common abbreviations that at times appear without reference.'''


[12] Dinesh K. Deelchand, Adam Berrington, Ralph Noeske, James M. Joers, Arvin Arani, Joseph Gillen, Michael Schar, Jon-Fredrik Nielsen, Scott Peltier, Navid Seraji-Bozorgzad, Karl Landheer, Christoph Juchem, Brian Soher, Douglas C. Noll, Kejal Kantarci, Eva M. Ratai, Thomas H. Marecii, Peter B. Barker, Gulin Oz (2019) Across-vendor standardization of semi-LASER for single-voxel MRS at 3T, NMR in Biomedicine. e4218 https://doi.org/10.1002/nbm.4218
'''**Reporting standards Lin A, Andronesi O, Bogner W, et al. Minimum reporting standards for in vivo magnetic resonance spectroscopy (MRSinMRS): experts' consensus recommendations. NMR Biomed. 2021;e4484.  https://doi.org/10.1002/nbm.4484 The second paper of a more general scope is concerned with minimal reporting guidelines for papers that include MRS data, whether published in MR literature or even more so in clinical journals. It has been a common experience for many of the experienced MRS methods experts to find essential details about employed MRS methods missing from published papers or in manuscripts submitted for review. Hence, Lin et al have assembled a list of items that the authors, who are all experienced referees, suggest should be covered in the methods section of future papers including MRS results. For ease of use, the paper also contains a checklist that could be submitted along with a manuscript as supplemental material or as a way to check that all vital information is provided in the methods section.'''


[13] Gulin Oz, Dinesh K. Deelchand, Jannie P. Wijnen, Vladimir Mlynarik, Lijing Xin, Ralf Mekle, Ralph Noeske, Tom W.J. Scheenen, Ivan Tkac, the Experts' Working Group on Advanced Single Voxel 1H MRS (2020) Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations, NMR in Biomedicine. e4236  https://doi.org/10.1002/nbm.4236
'''Checklist''' from https://doi.org/10.1002/nbm.4484


[14] L. Ryner, J Sorenson, M.A. Thomas (1995) Localized 2D J-resolved H-1 MR spectroscopy: Strong coupling effects in vitro and in vivo, Magn. Reson. Imaging 13:853–869 https://doi.org/10.1016/0730-725X(95)00031-B
MRI system description


[15] R. Schulte, T. Lange, J. Beck, D. Meier, P. Boesiger (2006) Improved two-dimensional J-resolved spectroscopy, NMR Biomed. 19:264–270  https://doi.org/10.1002/nbm.1027
a. Field strength, eg 1.5 T, 3 T, 7 T, 9.4 T


[16] Krish Krishnamurthy (2013) CRAFT (complete reduction to amplitude frequency table) – robust and time efficient Bayesian approach for quantitative mixture analysis by NMR, Magn. Reson. Chem. 51: 821–829  https://doi.org/10.1002/mrc.4022
b. Manufacturer, eg General Electric, Philips, Siemens, Toshiba


==Automated magnetic resonance spectroscopy voxel placement tools==
c. Model, eg General Electric Signa HD/X/T/de, Optima MR450/MR450W, Discovery MR750/MR750W, Signa Premier; Siemens Biograph mMR,Magnetom, Aera, Espree, Prisma, Skyra, Trio, Verio, Magnetom 7 T, Terra; Phillips Ingenia 1.5 T S, 3 T X/S, Elition 3 T X/S, Ambition 1.5 T X/S, Achieva 1.5 T/3 T. Software version, eg Siemens VB17A, VD19, VE11C; General Electric 12x-24x; Phillips Release 5, 5.1 (R1-3), 5.6, 6


Typically MRS data is collected within a single voxel that needs to be manually prescribed. To improve data collection quality, there has been anincreased interest and development of real-time single voxel automated prescription placement methods8. Researchers can now acquire MRS data in a routine way using a variety of automated voxel placement procedures. The procedures are used in real-time during data acquisition and have been streamlined for efficient usage and low time cost.
d. RF coils used (nuclei, number of channels, type, body part), eg 1H, 31P, 13C, 31P-1H; type, eg head/neck, torso, knee; if not manufacturer, design, eg
butterfly, quadrature etc


* One procedure uses non-linear warping between native subject space and template space (i.e., Montreal Neurological Institute [MNI] space) to identify precise voxel locations in scanner space that are based on MNI neuroanatomy.
e. Additional hardware, eg shim inserts, dielectric pads


* A second procedure is for the real-time in-scan session identification of precise coordinates from prior scanning sessions for MRS voxel placement based on person-specific coordinates. For example, if an initial scan session includes a functional task, information from that data can be used for subsequent voxel placement.


* A third procedure that is similar to second procedure above is using the central coordinate of an MRS voxel collected previously for placement in the same individual during a second scan session.
Acquisition parameters in full


i. Pulse sequence, eg spin-echo, point resolved spectroscopy (PRESS), stimulated echo acquisition mode (STEAM), semi-LASER, etc.


==Data Management==
ii. Location of volume(s) of interest (VOI(s)), eg posterior cingulate gyrus, M. tibialis anterior, internal capsule of prostate, etc. A figure that displays the VOI on anatomic images is recommended.


CNI currently uses Flywheel as its data base management system. A critical feature of this data base management is the ability to share computational methods within the system. The CNI now provides a combination of data repository and integrated open source processing tools such as Gannet [2] and LCModel [7]. This combination of tools supports scientific transparency for both data and computational sharing. Spectroscopy analysis methods such as LCModel can be containerized as a gear in Flywheel for automated processing and data visualization.
iii. Nominal VOI size [cm3, mm3], eg 40 × 40 × 10 mm3.


iv. Repetition time (TR), echo time (TE) [ms, s]; if STEAM, mixing time (TM).


[[Image:Flywheel_Fig.jpg|1200px|thumb|center|Flywheel]]
v. Total number of excitations per spectrum.


=Representative Research Studies=
vi. Additional sequence parameters, eg


Examples of studies at CNI using in-vivo spectroscopy techniques include characterization of biomarkers following transcranial magnetic stimulation, and metabolite characterization for conditions such as substance addiction, pain, depression, and various forms of dementia. These studies illustrate integrated data acquisition and data processing tools accessible to the CNI user community which simplify the use and sharing of spectroscopy results in neuroimaging applications.
i. Spectral width [Hz, kHz] and number of data points


[https://doi.org/10.1093/cercor/bhz332 Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability] DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332
ii. Frequency offset (if any)


=New Methods and Techniques=
iii. If magnetic resonance spectroscopic imaging (MRSI): specification of two-dimensional (2D) or three-dimensional (3D) spatial mapping, field of view (FOV), matrix size, acceleration factor, sampling/reconstruction method (eg parallel imaging, compressed sensing, spatial spectral encoding, etc), nominal and effective (ie final) voxel volumes, flip angles for fast MRSI


The CNI continues to support the research of its user community by developing and incorporating for general use new data acquisition and data analysis capabilities.
iv. For multidimensional acquisitions, number of encodings in the second spectral dimension


[https://doi.org/10.1002/mrm.26691 GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence] Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691
v. For editing methods, editing pulse information including pulse shape, bandwidth and offset frequency


=Spectroscopy Literature=
vi. For multinuclear sequences: details of decoupling or polarization transfer sequences and related parameters.


===Recent Literature===
''Papers presented at the ISMRM MR Spectroscopy Study Group Virtual Meeting: NMR in Biomedicine Special Issue Experts' Recommendations: Where Consensus Was Reached and Where Dissent Prevailed, Part 1 (November 12, 2020)''


[https://doi.org/10.1002/nbm.4504 Advanced methodology for in vivo magnetic resonance spectroscopy] In‐Young Choi Roland Kreis https://doi.org/10.1002/nbm.4504


[https://doi.org/10.1002/nbm.4350 B0 shimming for in vivo magnetic resonance spectroscopy: Experts' consensus recommendations] Christoph Juchem, Cristina Cudalbu, Robin A. de Graaf, Rolf Gruetter, Anke Henning, Hoby P. Hetherington, Vincent O. Boer NMR in Biomedicine 2020;e4350  https://doi.org/10.1002/nbm.4350
f. Water suppression method (and any other suppression methods used, eg lipid suppression, outer volume suppression).


[https://doi.org/10.1002/nbm.4309 Advanced magnetic resonance spectroscopic neuroimaging: Experts' consensus recommendations] Andrew A. Maudsley, Ovidiu C. Andronesi, Peter B. Barker, Alberto Bizzi, Wolfgang Bogner, Anke Henning, Sarah J. Nelson, Stefan Posse, Dikoma C. Shungu, Brian J. Soher NMR in Biomedicine 2020;e4309  https://doi.org/10.1002/nbm.4309
g. Shimming method, reference peak used for assessing shim performance, and thresholds for “acceptance of shim” chosen.


[https://doi.org/10.1002/nbm.4364 Motion correction methods for MRS: experts' consensus recommendations] Ovidiu C. Andronesi, Pallab K. Bhattacharyya, Wolfgang Bogner, In‐Young Choi, Aaron T. Hess, Phil Lee, Ernesta M. Meintjes, M. Dylan Tisdall, Maxim Zaitzev, André van der Kouwe NMR in Biomedicine 2020;e4364  https://doi.org/10.1002/nbm.4364
h. Triggering method, if used (respiratory, peripheral, cardiac triggering, including device used and delays).


[https://doi.org/10.1002/nbm.4257 Preprocessing, analysis and quantification in single‐voxel magnetic resonance spectroscopy: experts' consensus recommendations] Jamie Near Ashley D. Harris Christoph Juchem Roland Kreis Małgorzata Marjańska Gülin Öz Johannes Slotboom Martin Wilson Charles Gasparovic NMR in Biomedicine 2020;e4257  https://doi.org/10.1002/nbm.4257
i. Frequency and motion correction methods, if used (prospective or retrospective, external tracker or navigator method).


[https://doi.org/10.1002/nbm.4266 Proton magnetic resonance spectroscopy in skeletal muscle: Experts' consensus recommendations] Martin Krššák, Lucas Lindeboom, Vera Schrauwen‐Hinderling, Lidia S. Szczepaniak, Wim Derave, Jesper Lundbom, Douglas Befroy, Fritz Schick, Jürgen Machann, Roland Kreis, Chris Boesch NMR in Biomedicine 2020;e4266  https://doi.org/10.1002/nbm.4266


[https://doi.org/10.1002/nbm.4246 31P magnetic resonance spectroscopy in skeletal muscle: Experts' consensus recommendations] Martin Meyerspeer, Chris Boesch, Donnie Cameron, Monika Dezortová, Sean C. Forbes, Arend Heerschap, Jeroen A.L. Jeneson, Hermien E. Kan, Jane Kent, Gwenaël Layec, Jeanine J. Prompers, Harmen Reyngoudt, Alison Sleigh, Ladislav Valkovič, Graham J. Kemp, Experts' Working Group on 31P MR Spectroscopy of Skeletal Muscle NMR in Biomedicine 2020;e4246  https://doi.org/10.1002/nbm.4246   
Spectral quantification methods and parameters


a. Software package used to reconstruct and analyze the MRS data including MR manufacture software (eg General Electric PROBE, Siemens Syngo, or Phillips SpectroView) and/or third-party software packages (eg LCModel, jMRUI, TARQUIN, SIVIC, INSPECTOR, FID-A, BrainSpec, MIDAS, GANNET)


''Other review papers in the special issue now online''
b. Deviations in processing steps from quoted reference or product defaults


[https://doi.org/10.1002/nbm.4347 Terminology and concepts for the characterization of in vivo MR spectroscopy methods and MR spectra: Background and experts' consensus recommendations] Roland Kreis, Vincent Boer, In‐Young Choi, Cristina Cudalbu, Robin A. de Graaf, Charles Gasparovic,,Arend Heerschap, Martin Krššák, Bernard Lanz, Andrew A. Maudsley, Martin Meyerspeer, Jamie Near, Gülin Öz, Stefan Posse, Johannes Slotboom, Melissa Terpstra, Ivan Tkáč, Martin Wilson,  Wolfgang Bogner, Experts' Working Group on Terminology for MR Spectroscopy NMR in Biomedicine 2020;e4347  https://doi.org/10.1002/nbm.4347
c. Quantitative output measures


[https://doi.org/10.1002/nbm.4411 Spectral editing in 1H magnetic resonance spectroscopy: Experts' consensus recommendations] In‐Young Choi, Ovidiu C. Andronesi, Peter Barker, Wolfgang Bogner, Richard A. E. Edden, Lana G. Kaiser, Phil Lee,  Małgorzata Marjańska, Melissa Terpstra, Robin A. de Graaf NMR in Biomedicine 2020;e4411  https://doi.org/10.1002/nbm.4411
d. Quantification references and assumptions, model fitting assumptions


[https://doi.org/10.1002/nbm.4325 Magnetic resonance spectroscopy in the rodent brain: Experts' consensus recommendations] Bernard Lanz, Alireza Abaei, Olivier Braissant, In‐Young Choi, Cristina Cudalbu, Pierre‐Gilles Henry, Rolf Gruetter, Firat Kara, Kejal Kantarci, Phil Lee, Norbert W. Lutz, Małgorzata Marjańska, Vladimír Mlynárik, Volker Rasche, Lijing Xin, Julien Valette,  the Experts' Working Group on Magnetic resonance spectroscopy in the rodent brain NMR in Biomedicine 2020;e4325  https://doi.org/10.1002/nbm.4325


[https://doi.org/10.1002/nbm.4236 Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations] Gülin Öz  Dinesh K. Deelchand  Jannie P. Wijnen  Vladimír Mlynárik  Lijing Xin  Ralf Mekle  Ralph Noeske  Tom W.J. Scheenen  Ivan Tkáč  the Experts' Working Group on Advanced Single Voxel 1H MRS  https://doi.org/10.1002/nbm.4236 NMR in Biomedicine. 2020;e4236
Quality assurance. Studies must include the following


a. Reported variables (SNR, linewidth, and description of how they were obtained)


b. Data exclusion criteria


''Additional review and research papers''
c. Other quality measures from fitting software are also recommended (eg standard deviation (SD), Cramér-Rao lower bound (CRLB)), and/or the
robustness of the measures gained (repeatability measures if known)


[https://doi.org/10.1002/nbm.4218 Across‐vendor standardization of semi‐LASER for single‐voxel MRS at 3T] Dinesh K. Deelchand Adam Berrington Ralph Noeske James M. Joers Arvin Arani Joseph Gillen Michael Schär Jon‐Fredrik Nielsen Scott Peltier Navid Seraji‐Bozorgzad Karl Landheer Christoph Juchem Brian J. Soher Douglas C. Noll Kejal Kantarci Eva M. Ratai Thomas H. Mareci Peter B. Barker Gülin Öz NMR in Biomedicine.2019;e4218 https://doi.org/10.1002/nbm.4218
d. Figure showing representative spectra


[https://doi.org/10.1016/j.neuroimage.2019.01.056 Multi-vendor standardized sequence for edited magnetic resonance spectroscopy] Muhammad G.Saleh Daniel Rimbault Mark Mikkelsen Georg Oeltzschner Anna M.Wang Dengrong Jiang Ali Alhamud Jamie Near Michael Schär Ralph Noeske James B.Murdoch Lars Ersland Alexander R.Craven Gerard Eric Dwyer Eli Renate Grüner LiPann Sinyeob Ahnn Richard A.E.Edden Neuroimage 189 (2019) 425-431 https://doi.org/10.1016/j.neuroimage.2019.01.056


[https://doi.org/10.1016/j.neuroimage.2019.02.059 Big GABA II: Water-referenced edited MR spectroscopy at 25 research sites] MarkMikkelsen Daniel L.Rimbault Peter B.Barker Pallab K.Bhattacharyya Maiken K.Brix Pieter F.Buur Kim M.Cecil Kimberly L.Chanab David Y.-T.Chen Alexander R.Craven KoenCuypers MichaelDacko Niall W.Duncan UlrikeDydak David A.Edmondson GabrieleEnde LarsErsland Megan A.Forbes FeiGao IanGreenhouse Ashley D.Harris NayingHe StefanieHeba NigelHoggard Tun-WeiHsu Jacobus F.A.Jansen AlayarKangarlu ThomasLang R. MarcLebel YanLi Chien-Yuan E.Lin Jy-KangLiou Jiing-FengLirng FengLiu Joanna R.Long RuoyunMaq CelineMaes MartaMoreno-Ortega Scott O.Murray SeanNoah RalphNoeske Michael D.Noseworthy GeorgOeltzschner Eric C.Porges James J.Prisciandaro Nicolaas A.J.Puts Timothy P.L.Roberts MarkusSack NapaponSailasuta Muhammad G.Saleh Michael-PaulSchallmo NicholasSimard DiederickStoffers Stephan P.Swinnen MartinTegenthoff PeterTruong GuangbinWang Iain D.Wilkinson Hans-JörgWittsack Adam J.Woods HongminXu FuhuaYan ChenchengZhang VadimZipunnikov Helge J.Zöllner Richard A.E.Edden https://doi.org/10.1016/j.neuroimage.2019.02.059


[https://doi.org/10.1002/nbm.4058 Validation of in vivo MRS measures of metabolite concentrations in the human brain] Elvisha Dhamala Ines Abdelkefi Mavesa Nguyen T. Jay Hennessy Hélène Nadeau Jamie Near NMR in Biomedicine. 2019;32:4058 https://doi.org/10.1002/nbm.4058
'''*Four papers dealing with commonly used MRS acquisition sequences and processing methods.'''


[https://doi.org/10.1002/nbm.4206 In vivo diffusion‐weighted MRS using semi‐LASER in the human brain at 3 T: Methodological aspects and clinical feasibility] Guglielmo Genovese, Małgorzata Marjańska, Edward J. Auerbach, Lydia Yahia Cherif, Itamar Ronen, Stéphane Lehéricy, Francesca Branzoli NMR in Biomedicine 2020;e4206  https://doi.org/10.1002/nbm.4206
'''**Advanced single-voxel MRS Oz G, Deelchand DK, Wijnen JP, et al. Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: experts' consensus recommendations. NMR Biomed. 2020;e4236. https://doi.org/10.1002/nbm.4236'''


[https://doi.org/10.1002/nbm.4368 Correcting frequency and phase offsets in MRS data using robust spectral registration]Mark Mikkelsen, Sofie Tapper, Jamie Near, Stewart H. Mostofsky, Nicolaas A. J. Puts, Richard A. E. Edden NMR in Biomedicine 2020;e4368 https://doi.org/10.1002/nbm.4368
'''**Advanced neuro-MRSI Maudsley AA, Andronesi OC, Barker PB, et al. Advanced magnetic resonance spectroscopic neuroimaging: experts' consensus recommendations. NMR Biomed. 2020;e4309. https://doi.org/10.1002/nbm.4309'''


[https://doi.org/10.1002/nbm.4245 In vivo Glx and Glu measurements from GABA‐edited MRS at 3 T]Tiffany Bell, Elodie S. Boudes, Rachelle S. Loo, Gareth J. Barker, David J. Lythgoe, Richard A.E. Edden, R. Marc Lebel, Martin Wilson, Ashley D. Harris NMR in Biomedicine 2020;e4245 https://doi.org/10.1002/nbm.4245
'''**Spectral editing Choi IY, Andronesi OC, Barker P, et al. Spectral editing in 1H magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4411. https://doi.org/10.1002/nbm.4411'''


[https://doi.org/10.1002/nbm.4197 Influence of fitting approaches in LCModel on MRS quantification focusing on age‐specific macromolecules and the spline baseline] Małgorzata Marjańska, Melissa Terpstra NMR in Biomedicine 2019;e4197  https://doi.org/10.1002/nbm.4197
'''**Processing and quantification Near J, Harris AD, Juchem C, et al. Preprocessing, analysis and quantification in single-voxel magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4257. https://doi.org/10.1002/nbm.4257'''


[https://doi.org/10.1002/nbm.4093 Localized MRS reliability of in vivo glutamate at 3 T in shortened scan times: A feasibility study – Efforts to improve rigor and reproducibility] Randy P. Auerbach, Diego A. Pizzagalli NMR in Biomedicine 2019;e4093  https://doi.org/10.1002/nbm.4093


[https://doi.org/10.1016/j.neuroimage.2017.11.028 Insights into brain microstructure from in vivo DW-MRS] Marco Palombo, Noam Shemesh, Itamar Ronen, Julien Valette Neuroimage Volume 182, 15 November 2018, Pages 97-116 https://doi.org/10.1016/j.neuroimage.2017.11.028
*Three papers related to MRS techniques that are critical to ensure the quality of data.


**Water and lipid suppression Tkac I, Deelchand D, Dreher W, et al. Water and lipid suppression techniques for advanced 1H MRS and MRSI of the human brain: experts' consensus recommendations. NMR Biomed. 2020;e4459.  https://doi.org/10.1002/nbm.4459
   
**B0 shimming Juchem C, Cudalbu C, de Graaf RA, et al. B0 shimming for in vivo magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4350.  https://doi.org/10.1002/nbm.4350
   
**Motion correction Andronesi OC, Bhattacharyya PK, Bogner W, et al. Motion correction methods for MRS: experts' consensus recommendations. NMR Biomed. 2020;e4364.  https://doi.org/10.1002/nbm.4364




Several new publications here on advanced editing techniques - http://www.gabamrs.com/
*Four papers appertaining to special targets of MRS studies.


** Macromolecular signals and ways to accommodate them in1H MR brain spectra Cudalbu C, Behar KL, Bhattacharyya PK, et al. Contribution of macromolecules to brain 1H MR spectra: experts' consensus recommendations. NMR Biomed. 2020;e4393.  https://doi.org/10.1002/nbm.4393


''Voxel placement publication''
**1H MRS of skeletal muscle Krssak M, Lindeboom L, Schrauwen-Hinderling V, et al. Proton magnetic resonance spectroscopy in skeletal muscle: experts' consensus recommendations. NMR Biomed. 2020;e4266. https://doi.org/10.1002/nbm.4266
   
**31P MRS of skeletal muscle Meyerspeer M, Boesch C, Cameron D, et al. 31P magnetic resonance spectroscopy in skeletal muscle: experts' consensus recommendations. NMR Biomed. 2020;e4246.  https://doi.org/10.1002/nbm.4246
   
**Specifics for MRS methods in preclinical applications Lanz B, Abaei A, Braissant O, et al. Magnetic resonance spectroscopy in the rodent brain: experts' consensus recommendations. NMR Biomed. 2020;e4325.  https://doi.org/10.1002/nbm.4325


[https://doi.org/10.1002/mrm.27203 AutoVOI: real‐time automatic prescription of volume‐of‐interest for single voxel spectroscopy] Young Woo Park Dinesh K. Deelchand James M. Joers Brian Hanna Adam Berrington Joseph S. Gillen Kejal Kantarci Brian J.Soher Peter B. Barker HyunWook Park Gülin Öz Christophe Lenglet Magn Reson MEd. 2018;80:1787-1798 https://doi.org/10.1002/mrm.27203




''New open-source processing package currently under evaluation -''
*This special issue also includes authoritative reviews of the current state of


[https://doi.org/10.1016/j.jneumeth.2020.108827 Osprey: Open-source processing, reconstruction & estimation of magnetic resonance spectroscopy data] Georg Oeltzschner Helge J.Zöllner Steve C.N.Hui Mark Mikkelsen Muhammad G.Saleh Sofie Tapper Richard A.E. Edden Journal of Neuroscience Methods
**fast MRSI methodology Bogner W, Otazo R, Henning A. Accelerated MR spectroscopic imaging—a review of current and emerging techniques. NMR Biomed. 2020;e4314. https://doi.org/10.1002/nbm.4314
Volume 343, 1 September 2020, 108827 https://doi.org/10.1016/j.jneumeth.2020.108827 


**hyperpolarized 13C MRI and MRS Crane JC, Gordon JW, Chen H-Y, et al. Hyperpolarized 13C MRI data acquisition and analysis in prostate and brain at University of California, San Francisco. NMR Biomed. 2020;e4280.  https://doi.org/10.1002/nbm.4280


''Presentation at 2020 ENC Meeting - Accelerated MR spectroscopic imaging—a review of current and emerging techniques''
**functional MRS in rodents Just N. Proton functional magnetic resonance spectroscopy in rodents. NMR Biomed. 2020;e4254.  https://doi.org/10.1002/nbm.4254


[https://doi.org/10.1002/nbm.4314 Accelerated MR spectroscopic imaging—a review of current and emerging techniques] Wolfgang Bogner Ricardo Otazo Anke Henning NMR in Biomedicine.2020;e4314 https://doi.org/10.1002/nbm.4314


*Fifteen proferred original research contributions complete this special issue. They cover latest research results in terms of novel advanced MRS methodology or its application. The methodology addresses issues in
'''**standardization  - Deelchand DK, Berrington A, Noeske R, et al. Across-vendor standardization of semi-LASER for single-voxel MRS at 3T. NMR Biomed. 2019;e4218.  https://doi.org/10.1002/nbm.4218'''


WIPs Information:
**diffusion MRS Lundell H, Ingo C, Dyrby TB, Ronen I. Cytosolic diffusivity and microscopic anisotropy of N-acetyl aspartate in human white matter with diffusion-weighted MRS at 7 T. NMR Biomed. 2020;e4304.  https://doi.org/10.1002/nbm.4304 Hanstock C, Beaulieu C. Rapid acquisition diffusion MR spectroscopy of metabolites in human brain. NMR Biomed. 2020;e4270.  https://doi.org/10.1002/nbm.4270 Genovese G, Marjańska M, Auerbach EJ, et al. In vivo diffusion-weighted MRS using semi-LASER in the human brain at 3 T: methodological aspects and clinical feasibility. NMR Biomed. 2020;e4206. https://doi.org/10.1002/nbm.4206
**editing Deelchand DK, Marjańska M, Henry P-G, Terpstra M. MEGA-PRESS of GABA+: influences of acquisition parameters. NMR Biomed. 2019;e4199. https://doi.org/10.1002/nbm.4199 Ma RE, Murdoch JB, Bogner W, Andronesi O, Dydak U. Atlas-based GABA mapping with 3D MEGA-MRSI: cross-correlation to single-voxel MRS. NMR Biomed. 2020;e4275.  https://doi.org/10.1002/nbm.4275 Bell T, Boudes ES, Loo RS, et al. In vivo Glx and Glu measurements from GABA-edited MRS at 3 T. NMR Biomed. 2020;e4245.  https://doi.org/10.1002/nbm.4245


[1] J. Star-Lack et al., In Vivo Lactate Editing with Simultaneous Detection of Choline, Creatine, NAA, and Lipid Singlets at 1.5 T Using PRESS Excitation with Applications to the Study of Brain andHead and Neck Tumors, J Magn Reson, 133: 243 – 254 (1998) https://doi.org/10.1006/jmre.1998.1458
**novel acquisition techniques Kulpanovich A, Tal A. What is the optimal schedule for multiparametric MRS? A magnetic resonance fingerprinting perspective. NMR Biomed. 2019;e4196.  https://doi.org/10.1002/nbm.4196 Posse S, Sa De La Rocque Guimaraes B, Hutchins-Delgado T, et al. On the acquisition of the water signal during water suppression: high-speed MR spectroscopic imaging with water referencing and concurrent functional MRI. NMR Biomed. 2020;e4261.  https://doi.org/10.1002/nbm.4261
**processing techniques Francischello R, Geppi M, Flori A, Vasini EM, Sykora S, Menichetti L. Application of low-rank approximation using truncated singular value decomposition for noise reduction in hyperpolarized 13C NMR spectroscopy. NMR Biomed. 2020;e4285.  https://doi.org/10.1002/nbm.4285 Marjańska M, Terpstra M. Influence of fitting approaches in LCModel on MRS quantification focusing on age-specific macromolecules and the spline baseline. NMR Biomed. 2019;e4197. https://doi.org/10.1002/nbm.4197 Landheer K, Swanberg KM, Juchem C. Magnetic resonance Spectrum simulator (MARSS), a novel software package for fast and computationally efficient basis set simulation. NMR Biomed. 2019;e4129.  https://doi.org/10.1002/nbm.4129


[2] M. Mikkelsen et al., Big GABA: Edited MR spectroscopy at 24 research sites, NeuroImage, 159, 32 – 45, (2017) https://doi.org/10.1016/j.neuroimage.2017.07.021
**reported applications probe the feasibility of novel uses of advanced MRS methods van Houtum Q, Mohamed Hoesein FAA, Verhoeff JJC, et al. Feasibility of 31P spectroscopic imaging at 7 T in lung carcinoma patients. NMR Biomed. 2019;e4204.  https://doi.org/10.1002/nbm.4204 Rioux JA, Hewlett M, Davis C, et al. Mapping of fatty acid composition with free-breathing MR spectroscopic imaging and compressed sensing. NMR Biomed. 2019;e4241.  https://doi.org/10.1002/nbm.4241 Peeters TH, van Uden MJ, Rijpma A, Scheenen TWJ, Heerschap A. 3D 31P MR spectroscopic imaging of the human brain at 3 T with a 31P receive array: an assessment of 1H decoupling, T1 relaxation times, 1H-31P nuclear Overhauser effects and NAD+. NMR Biomed. 2019;e4169.  https://doi.org/10.1002/nbm.4169


[3] M.G. Saleh et al., Multi-vendor standardized sequence for edited magnetic resonance spectroscopy, NeuroImage, (2019) https://doi.org/10.1016/j.neuroimage.2019.01.056


[1] G. Öz et al., Short-Echo, Single-Shot, Full-Intensity Proton Magnetic Resonance Spectroscopy for Neurochemical Profiling at 4 T: Validation in the Cerebellum andBrainstem, Magn Reson Med, 65: 901 – 910 (2011)  https://doi.org/10.1002/mrm.22708


[2] VO. Boer et al., 7-T 1H MRS with adiabatic refocusing at short TE using radiofrequency focusing with a dualchannel volume transmit coil, NMR Biomed, 24(9), 1038 – 1046, (2011)  https://doi.org/10.1002/nbm.1641


[3] TW. Scheenen et al., Short Echo Time 1H-MRSI of the Human Brain at 3T With Minimal Chemical Shift Displacement Errors Using Adiabatic Refocusing Pulses, Magn Reson Med, 59: 1 – 6 (2008)  https://doi.org/10.1002/mrm.21302
Several new publications here on advanced editing techniques - http://www.gabamrs.com/


----


''Voxel placement publication''


[https://doi.org/10.1002/mrm.27203 AutoVOI: real‐time automatic prescription of volume‐of‐interest for single voxel spectroscopy] Young Woo Park Dinesh K. Deelchand James M. Joers Brian Hanna Adam Berrington Joseph S. Gillen Kejal Kantarci Brian J.Soher Peter B. Barker HyunWook Park Gülin Öz Christophe Lenglet Magn Reson MEd. 2018;80:1787-1798 https://doi.org/10.1002/mrm.27203




Spectroscopy
''New open-source processing package currently under evaluation -''


For users who are totally new to spectroscopy a good basic reference is [http://searchworks.stanford.edu/view/6725742 MRI From Picture to Proton] Donald W. McRobbie, Elizabeth A. Moore, Martin J. Graves, and Martin Prince, Cambridge University Press, Second Edition 2007, Chapter 15 (It's not just squiggles: in vivo spectroscopy). This chapter describes spectroscopy from the clinical side, but covers the basics for both data acquisition and processing.
[https://doi.org/10.1016/j.jneumeth.2020.108827 Osprey: Open-source processing, reconstruction & estimation of magnetic resonance spectroscopy data] Georg Oeltzschner Helge J.Zöllner Steve C.N.Hui Mark Mikkelsen Muhammad G.Saleh Sofie Tapper Richard A.E. Edden Journal of Neuroscience Methods
Volume 343, 1 September 2020, 108827 https://doi.org/10.1016/j.jneumeth.2020.108827 


Books:


[http://onlinelibrary.wiley.com/book/10.1002/9780470512968;jsessionid=5537E205EAAA89060F0EE654DB7CAD21.f02t01 In Vivo NMR Spectroscopy, 2nd Edition, Author: Robin de Graaf, Wiley Online Library]
''Presentation at 2020 ENC Meeting - Accelerated MR spectroscopic imaging—a review of current and emerging techniques''


A recently published book [http://www.sciencedirect.com/science/book/9780124016880 Magnetic Resonance Spectroscopy - Tools for Neuroscience Research and Emerging Clinical Applications]
[https://doi.org/10.1002/nbm.4314 Accelerated MR spectroscopic imaging—a review of current and emerging techniques] Wolfgang Bogner Ricardo Otazo Anke Henning NMR in Biomedicine.2020;e4314 https://doi.org/10.1002/nbm.4314


=Collecting Data - available sequences and protocols, how-to guides=
=Spectroscopy Data Acquisition Tools at CNI=


==Spectroscopy Sequences==


'''Current spectroscopy sequences include methods for multi-metabolite data acquisition (Optimized-PRESS [4], [5], [6]) and semi-LASER [9], [10], [11], [12], [13]) and for edited GABA (gamma-Aminobutyric acid) specific data acquisition (MEGA-PRESS [1])'''
The Stanford CNI effort has become a best practice through a community effort with spectroscopy expertise from CNI staff, MRI scientists, and an expanding user community. Current spectroscopy sequences include methods both for edited GABA (gamma-Aminobutyric acid) specific data acquisition (MEGA-PRESS [1] and IM-SPECIAL [3]), and for multi-metabolite data acquisition (Optimized-PRESS [4], [5], [6]) and semi-LASER [9], [10], [11], [12], [13] Most sequences are linked to automatic processing pipelines in CNI's data management system, Flywheel, as referenced in the table below.




'''This protocol (spectro-protocol-1 located in the CNI Other tab on the scanner) contains the optimized-PRESS and sLaser sequences for data collection for all metabolites'''
{| class="wikitable"
|-
! Spectroscopy Sequence
! Measured Metabolites
! Analysis Methods
|-
|MEGA-PRESS [1]
|GABA+, Glx(Glutamate, Glutmine)
|Gannet [2]
|-
|IM-SPECIAL [3]
|GABA, Glu(Glutamate), Glx(Glutamate, Glutamine)
|Sequence specific Matlab code
|-
|Optimized-PRESS [4], [5], [6]
|All metabolites
|LCModel fitting [7]
|-
|semi-LASER [9], [10], [11], [12], [13]
|All metabolites
|LCModel fitting [7]
|}


[[File:Spectro-protocol-1.png|none|500px|spectro-protocol-1]]


References


[1] Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression, NMR Biomed. 11:266–272  https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291099-1492%28199810%2911%3A6%3C266%3A%3AAID-NBM530%3E3.0.CO%3B2-J


[2] Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris, Peter B. Barker, and C. John Evans (2014) Gannet: A Batch-Processing Tool for the Quantitative Analysis of Gamma-Aminobutyric Acid–Edited MR Spectroscopy Spectra, Journal of Magnetic Resonance Imaging 40:1445–1452  https://doi.org/10.1002/jmri.24478


'''optimized-PRESS'''
[3] Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47  https://doi.org/10.1002/mrm.26691


[4] Webb PG, Sailasuta N, Kohler SJ, Raidy T, Moats RA, Hurd R (1994) Automated single voxel proton MRS: technical development and multisite verification, Magnetic Resonance in Medicine 31(4):365-373 https://doi.org/10.1002/mrm.1910310404
[4] Webb PG, Sailasuta N, Kohler SJ, Raidy T, Moats RA, Hurd R (1994) Automated single voxel proton MRS: technical development and multisite verification, Magnetic Resonance in Medicine 31(4):365-373 https://doi.org/10.1002/mrm.1910310404


[5] Bodenhausen G, Freeman R, Turner DL (1977) Suppression of artifacts in two dimensional J spectroscopy, Journal of Magnetic Resonance Imaging 27:511-514 https://doi.org/10.1016/0022-2364(77)90016-6
[5] Bodenhausen G, Freeman R, Turner DL (1977) Suppression of artifacts in two dimensional J spectroscopy, Journal of Magnetic Resonance Imaging 27:511-514 https://doi.org/10.1016/0022-2364(77)90016-6  


[6] Tran TK, Vigneron DB, Sailasuta N, Tropp J, Le Roux P, Kurhanewicz J, Nelson S, Hurd R (2000) Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer, Magnetic Resonance in Medicine 43(1):23-33. https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291522-2594%28200001%2943%3A1%3C23%3A%3AAID-MRM4%3E3.0.CO%3B2-E  
[6] Tran TK, Vigneron DB, Sailasuta N, Tropp J, Le Roux P, Kurhanewicz J, Nelson S, Hurd R (2000) Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer, Magnetic Resonance in Medicine 43(1):23-33. https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291522-2594%28200001%2943%3A1%3C23%3A%3AAID-MRM4%3E3.0.CO%3B2-E


{|
[7] Provencher SW (2001) Automatic quantitation of localized in vivo1H spectra with LCModel, NMR in Biomedicine 14(4):260-264  https://doi.org/10.1002/nbm.698
|[[File:optimized-press-1.png|300px|thumb|left|optimized-press]]
 
|[[File:optimized-press-2.png|300px|thumb|left|optimized-press]]
[8] Young Woo Park, Dinesh K. Deelchand, James M. Joers, Brian Hanna, Adam Berrington, Joseph S. Gillen, Kejal Kantarci, Brian J. Soher, Peter B. Barker, HyunWook Park, Gulin Oz, Christophe Lenglet (2018) AutoVOI: real-time automatic prescription of volume-of-interest for single voxel spectroscopy, Magn. Reson. Med. 80:1787–1798  https://doi.org/10.1002/mrm.27203
|[[File:optimized-press-3.png|300px|thumb|left|optimized-press]]  
 
|}
[9] Scheenen TWJ, Klomp DWJ, Wijnen JP, Heerschap A. (2018) Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses, Magn. Reson. Med. 59(1):1-6  https://doi.org/10.1002/mrm.21302
 
[10] Oz G, Tkac I. (2011) Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem, Magn. Reson. Med. 65(4):901-910  https://doi.org/10.1002/mrm.22708
 
[11] Martin Wilson, Ovidiu Andronesi, Peter B. Barker, Robert Bartha, Alberto Bizzi, Patrick J. Bolan, Kevin M. Brindle, In-Young Choi, Cristina Cudalbu, Ulrike Dydak, Uzay E. Emir, Ramon G. Gonzalez, Stephan Gruber, Rolf Gruetter, Rakesh K. Gupta, Arend Heerschap, Anke Henning,Hoby P. Hetherington, Petra S. Huppi, Ralph E. Hurd, Kejal Kantarci, Risto A Kauppinen, Dennis W. J. Klomp, Roland Kreis, Marijn J. Kruiskamp, Martin O. Leach, Alexander P. Lin, Peter R. Luijten, Malgorzata Marjanska, Andrew A. Maudsley, Dieter J. Meyerhoff, Carolyn E. Mountford, Paul G. Mullins, James B. Murdoch, Sarah J. Nelson, Ralph Noeske, Gulin Oz, Julie W. Pan, Andrew C. Peet, Harish Poptani, Stefan Posse, Eva-Maria Ratai, Nouha Salibi, Tom W. J. Scheenen, Ian C. P. Smith, Brian J. Soher, Ivan Tkac, Daniel B. Vigneron, Franklyn A. Howe (2019) Methodological consensus on clinical proton MRS of the brain:Review and recommendations, Magn. Reson. Med. 82:527–550 https://doi.org/10.1002/mrm.27742


[12] Dinesh K. Deelchand, Adam Berrington, Ralph Noeske, James M. Joers, Arvin Arani, Joseph Gillen, Michael Schar, Jon-Fredrik Nielsen, Scott Peltier, Navid Seraji-Bozorgzad, Karl Landheer, Christoph Juchem, Brian Soher, Douglas C. Noll, Kejal Kantarci, Eva M. Ratai, Thomas H. Marecii, Peter B. Barker, Gulin Oz (2019) Across-vendor standardization of semi-LASER for single-voxel MRS at 3T, NMR in Biomedicine. e4218  https://doi.org/10.1002/nbm.4218


'''s-Laser'''
[13] Gulin Oz, Dinesh K. Deelchand, Jannie P. Wijnen, Vladimir Mlynarik, Lijing Xin, Ralf Mekle, Ralph Noeske, Tom W.J. Scheenen, Ivan Tkac, the Experts' Working Group on Advanced Single Voxel 1H MRS (2020) Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations, NMR in Biomedicine. e4236  https://doi.org/10.1002/nbm.4236


High field (3T) and ultra-high field (7T) are ideal field strength for MR spectroscopy due to the higher spectral resolution and higher signal that can be achieved. But with these advantages comes a higher B1-inhomogeneity and larger Chemical Shift Displacement Error (CSDE). Semi-LASER is a double spin-echo MRS technique like the established PRESS (GE product name Probe-P) technique that uses a slice selective non-adiabatic excitation and two pairs of adiabatic slice selective refocusing pulses for volume selection. The adiabatic behavior of the RF pulses addresses the B1-inhomogeneity problem while the increased bandwidth of these pulses reduces the CSDE.
==Current CNI spectroscopy protocols==


'''There are two CNI spectroscopy protocols'''


[9] Scheenen TWJ, Klomp DWJ, Wijnen JP, Heerschap A. (2018) Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses, Magn. Reson. Med. 59(1):1-6 https://doi.org/10.1002/mrm.21302
'''(1) The protocol spectro-protocol-1 located in the CNI "Other" tab on the scanner has the sLaser and optimized-PRESS sequences for data collection for all metabolites. For new studies users should use the sLaser sequence. For longitudinal studies the optimized-PRESS sequence can be continued to be used.'''


[10] Oz G, Tkac I. (2011) Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem, Magn. Reson. Med. 65(4):901-910 https://doi.org/10.1002/mrm.22708
'''(2) The protocol spectro-protocol-1 - editing located in the CNI "Other" tab on the scanner has the MEGA-PRESS sequence for data collection for GABA.'''


[11] Martin Wilson, Ovidiu Andronesi, Peter B. Barker, Robert Bartha, Alberto Bizzi, Patrick J. Bolan, Kevin M. Brindle, In-Young Choi, Cristina Cudalbu, Ulrike Dydak, Uzay E. Emir, Ramon G. Gonzalez, Stephan Gruber, Rolf Gruetter, Rakesh K. Gupta, Arend Heerschap, Anke Henning,Hoby P. Hetherington, Petra S. Huppi, Ralph E. Hurd, Kejal Kantarci, Risto A Kauppinen, Dennis W. J. Klomp, Roland Kreis, Marijn J. Kruiskamp, Martin O. Leach, Alexander P. Lin, Peter R. Luijten, Malgorzata Marjanska, Andrew A. Maudsley, Dieter J. Meyerhoff, Carolyn E. Mountford, Paul G. Mullins, James B. Murdoch, Sarah J. Nelson, Ralph Noeske, Gulin Oz, Julie W. Pan, Andrew C. Peet, Harish Poptani, Stefan Posse, Eva-Maria Ratai, Nouha Salibi, Tom W. J. Scheenen, Ian C. P. Smith, Brian J. Soher, Ivan Tkac, Daniel B. Vigneron, Franklyn A. Howe (2019) Methodological consensus on clinical proton MRS of the brain:Review and recommendations, Magn. Reson. Med. 82:527–550 https://doi.org/10.1002/mrm.27742


[12] Dinesh K. Deelchand, Adam Berrington, Ralph Noeske, James M. Joers, Arvin Arani, Joseph Gillen, Michael Schar, Jon-Fredrik Nielsen, Scott Peltier, Navid Seraji-Bozorgzad, Karl Landheer, Christoph Juchem, Brian Soher, Douglas C. Noll, Kejal Kantarci, Eva M. Ratai, Thomas H. Marecii, Peter B. Barker, Gulin Oz (2019) Across-vendor standardization of semi-LASER for single-voxel MRS at 3T, NMR in Biomedicine. e4218 https://doi.org/10.1002/nbm.4218
'''(1) Protocol screen shot: Spectro-protocol-1'''


[13] Gulin Oz, Dinesh K. Deelchand, Jannie P. Wijnen, Vladimir Mlynarik, Lijing Xin, Ralf Mekle, Ralph Noeske, Tom W.J. Scheenen, Ivan Tkac, the Experts' Working Group on Advanced Single Voxel 1H MRS (2020) Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations, NMR in Biomedicine. e4236 https://doi.org/10.1002/nbm.4236
[[File:Spectro-protocol-1.png|none|1000px|spectro-protocol-1]]


{|
{| class="wikitable"
|[[File:slaser30-1.png|300px|thumb|left|s-Laser]]
|-
|[[File:slaser-2.png|300px|thumb|left|s-Laser]]
! Spectroscopy Sequence
|[[File:slaser-3.png|300px|thumb|left|s-Laser]] 
! Description and General Information
! Parameters for Publications corresponding to the GE CV's of those parameters
|-
|Localizer
|
|
|-
|T1
|High Resolution T1 with automatic reformatting for sagittal, coronal, and axial views.
|
|-
|T2
|
|
|-
|Voxel Placement
|Sequence for rotated voxel placement (details described in separate section further below)
|
|-
|s-Laser
|This sequence is the GE "Works in Progress" and is consistent with the ISMRM Experts' consensus recommendations for this sequence."High field (3T) and ultra-high field (7T) are ideal field strength for MR spectroscopy due to the higher spectral resolution and higher signal that can be achieved. But with these advantages comes a higher B1-inhomogeneity and larger Chemical Shift Displacement Error (CSDE). Semi-LASER is a double spin-echo MRS technique like the established PRESS (GE product name Probe-P) technique that uses a slice selective non-adiabatic excitation and two pairs of adiabatic slice selective refocusing pulses for volume selection. The adiabatic behavior of the RF pulses addresses the B1-inhomogeneity problem while the increased bandwidth of these pulses reduces the CSDE."
|
|-
|Optimized-PRESS
|This sequence is a GE "Works in Progress" and is consistent with the ISMRM Experts' consensus recommendations for this sequence. This is currently considered a legacy sequence.
|
|}
|}




'''This protocol (spectro-protocol-editing-1 located in the CNI Other tab on the scanner) contains the MEGA-PRESS sequence for data collection for GABA edited data'''


[[File:Spectro-editing-protocol-1.png|none|500px|spectro-editing-protocol-1]]




''' Screen shots of parameters and CV's for s-laser sequence'''


'''MEGA-PRESS'''
{|
|[[File:slaser30-1.png|600px|thumb|left|Figure 1 s-Laser]]
|[[File:slaser-2.png|600px|thumb|left|Figure 2 s-Laser]]
|[[File:slaser-3.png|600px|thumb|left|Figure 3 s-Laser]] 
|}


[1] Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression, NMR Biomed. 11:266–272 https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291099-1492%28199810%2911%3A6%3C266%3A%3AAID-NBM530%3E3.0.CO%3B2-J
''' Screen shots of parameters and CV's for optimized-press sequence'''


{|
{|
|[[File:spectro-GABA-1.png|300px|thumb|left|MEGA-PRESS]]
|[[File:optimized-press-1.png|600px|thumb|left|Figure 1 optimized-press]]
|[[File:spectro-GABA-2.png|300px|thumb|left|MEGA-PRESS]]
|[[File:optimized-press-2.png|600px|thumb|left|Figure 2 optimized-press]]
|[[File:spectro-GABA-3.png|300px|thumb|left|MEGA-PRESS]]
|[[File:optimized-press-3.png|600px|thumb|left|Figure 3 optimized-press]]   
|[[File:spectro-GABA-4.png|300px|thumb|left|MEGA-PRESS]]
|[[File:spectro-GABA-6.png|300px|thumb|left|MEGA-PRESS]]   
|}
|}


=Processing and Analyis of data with Flywheel, how-to guides=


Note: For users using the CNI "nfl" sequence with LCModel data analysis -
Users who are in groups that are not themselves Flywheel "Lab" customers will need to download their results from the session tab now (not the analyses tab as was done before and shown in the figure below)


MEGA-PRESS results will continue to be in the analyses tab.




[[Image:Screen Shot LCModel Session.png|1200px|thumb|center|LCModel Results]]
'''(2) Protocol screen shot:Spectro-protocol-editing-1'''


=Processing and Analyzing GABA Data - non-Flywheel methods, how-to guides=
[[File:Spectro-editing-protocol-1.png|none|1000px|spectro-editing-protocol-1]]


(1) Analysis of GABA Data collected with the MEGA-PRESS sequence with Gannet
{| class="wikitable"
|-
! Spectroscopy Sequence
! Description and General Information
! Parameters for Publications corresponding to the GE CV's of those parameters
|-
|Localizer
|
|
|-
|T1
|High Resolution T1 with automatic reformatting for sagittal, coronal, and axial views.
|
|-
|T2
|
|
|-
|Voxel Placement
|Sequence for rotated voxel placement (details described in separate section further below)
|
|-
|MEGA-PRESS
|The current spectroscopy sequence for edited GABA (gamma-Aminobutyric acid) data acquisition is MEGA-PRESS. This sequence is the GE "Works in Progress" (Rx28) and is consistent with the ISMRM Experts' consensus recommendations for this sequence. The only modification of the CNI version from the GE Works in progress is the value of TR (CNI TR = 2000, changed from TR = 1800)


MEGA-PRESS description for publications - Example MEGA-PRESS description for publication from [https://doi.org/10.1093/cercor/bhz332 Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability] DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332, Additional example sequence description from GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691
Screen shots of the current MEGA-PRESS sequence are shown below. Figures 1-3 display all parameters and CV's. With this sequence the spectra are processed automatically and stored (Figure 4). The data can be inspected via the GE scanner data viewer (Figure 5).
|MRI system description
* MRI scanning sessions were completed at the Stanford Center for Cognitive and Neurobiological Imaging. Images were acquired using a 3T GE Discovery UHP MR scanner and 32-channel Nova head coil.
Acquisition parameters
* For each participant, high-resolution T1-weighted 3D Bravo sagittal scans (1.0 mm3 voxels) were acquired towards the start of the scanning session and used for accurate placement of the MRS voxels.
* Single voxel in-vivo 1H MRS scans were acquired using a MEGA-PRESS sequence (Mescher et al. 1998)
* editing pulses: 14 ms 180° Gaussian-weighted sinc pulses (CV19, CV22)
* applied at 1.9/7.5 ppm (CV20, CV21)
* with TE/TR = 68 ms/2000 ms, respectively
* Volumes were shimmed at the start of each MRS scan.
* The GABA editing was performed on a 20 x 20 x 20 mm voxel
* 128 transients were acquired (CV4)
* with a scan time of 9 min 20 s
|}


To analyze the data from MEGA-PRESS experiments, we recommend Gannet, a batch-analysis tool for GABA-edited MRS data. The Gannet code and instruction manual can be downloaded from here [http://gabamrs.blogspot.com/ gabamrs.blogspot.com] Additional and newer information can be found here [http://www.gabamrs.com/ www.gabamrs.com] and here [http://www.gabamrs.com/about/ www.gabamrs.com/about/]  Note that Matlab with Optimization and Statistics Toolboxes must be installed on your computer prior to downloading the Gannet2.0 code.
''' Screen shots of parameters and CV's for MEGA-PRESS sequence'''


{|
|[[File:spectro-GABA-1.png|600px|thumb|left|Figure 1 MEGA-PRESS]]
|[[File:spectro-GABA-2.png|600px|thumb|left|Figure 2 MEGA-PRESS]]
|[[File:spectro-GABA-3.png|600px|thumb|left|Figure 3 MEGA-PRESS]]
|}


Note that following change needs to be made to the Gannet code in order to correctly analyze data obtained the CNI MEGA-PRESS sequence [http://gabamrs.blogspot.com/ gabamrs.blogspot.com] (When Gannet goes wrong section)




From gabamrs blogspot -
{|
Solution 2: ON and OFF are incorrectly identified.
|[[File:spectro-GABA-4.png|600px|thumb|left|Figure 4 MEGA-PRESS]]
If the creatine stripe is correct (red on blue; spectra phased positively) and the difference spectra are still negative, then the issue is the ordering of ON and OFF spectra.  The simple solution is to change the MRS_struct.p.onofforder parameter in GannetPreInitialise.m. It is either 'onfirst' or 'offfirst' depending on the acquisition order.
|[[File:spectro-GABA-6.png|600px|thumb|left|Figure 5 MEGA-PRESS]] 
So here's the summary:
|}
"Gannet makes my GABA difference spectra negative".
"Are your creatine signals phased positively?".
If yes, change MRS_struct.p.onofforder; if no, change MRS_struct.p.WaterPositive.


=Notes on Spectro Scans on DV26=
==Prescribing a rotated voxel==
==Prescribing a rotated voxel==
At the moment GE’s DV26 software platform release doesn’t support voxel rotation for spectroscopy sequences. A workaround however is available:
At the moment GE’s DV26 and higher software platforms release doesn’t support voxel rotation for spectroscopy sequences. A workaround however is available:


(1) After the 3-plane reconstruction of the T1w images, setup a 3D imaging scan. We saved a template of this 3D scan in the protocol “CNI Example Spectroscopy” and named it as “Voxel prescription”. Add this sequence to your protocol and put it before the MRS scan.
(1) After the 3-plane reconstruction of the T1w images, setup a 3D imaging scan. We saved a template of this 3D scan in the protocol “CNI Example Spectroscopy” and named it as “Voxel prescription”. Add this sequence to your protocol and put it before the MRS scan.
Line 326: Line 416:
To look for this information on [https://cni.flywheel.io Flywheel], open the information window of the p-file, and search for op_user_8, op_user_9, op_user_10, etc.
To look for this information on [https://cni.flywheel.io Flywheel], open the information window of the p-file, and search for op_user_8, op_user_9, op_user_10, etc.


=Spectroscopy Data Processing Tools at CNI=
==Data Management==
CNI currently uses Flywheel as its data base management system. A critical feature of this data base management is the ability to share computational methods within the system. The CNI now provides a combination of data repository and integrated open source processing tools such as Gannet [2] and LCModel [7]. This combination of tools supports scientific transparency for both data and computational sharing. Spectroscopy analysis methods such as LCModel can be containerized as a gear in Flywheel for automated processing and data visualization.
[[Image:Flywheel_Fig.jpg|1200px|thumb|center|Flywheel]]
==Current CNI spectroscopy Flywheel gears==
'''Each of the supported spectroscopy sequences is linked to a Flywheel gear for automatic data processing'''
{| class="wikitable"
|-
! Spectroscopy Sequence
! Measured Metabolites
! Analysis Methods
|-
|semi-Laser
|All metabolites
|Sequence specific Matlab code, LCModel fitting  - Flywheel processing gear placeholder information here: LCMODEL_r_dlpfc_nfl_[BASIS_SET=02_01_19,FIXED_NAA=0]_(2021-05-13)
|-
|Optimmized_PRESS
|All metabolites
|Sequence specific Matlab code, LCModel fitting  - Flywheel processing gear placeholder information here: LCMODEL_r_dlpfc_nfl_[BASIS_SET=02_01_19,FIXED_NAA=0]_(2021-05-13)
|-
|MEGA-PRESS
|GABA+, Glx(Glutamate, Glutmine)
|To analyze the data from MEGA-PRESS experiments, we recommend Gannet, a batch-analysis tool for GABA-edited MRS data http://www.gabamrs.com/. Currently the latest version 3.1 is Docker containerized. This needs to be manually run, but this analysis method will soon be changed to a Flywheel gear for automatic analysis and storage of results (see location of data analysis results section below).
References from the Gannet web site include:
Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris, Peter B. Barker, and C. John Evans (2014) Gannet: A Batch-Processing Tool for the Quantitative Analysis of Gamma-Aminobutyric Acid–Edited MR Spectroscopy Spectra, Journal of Magnetic Resonance Imaging 40:1445–1452 https://doi.org/10.1002/jmri.24478
Paul G.Mullins David J.McGonigle Ruth L.O'Gorman Nicolaas A.J.Puts RishmaVidyasagar C. JohnEvans Cardiff Symposium on MRS of GABA Richard A.E.Edden Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA https://doi.org/10.1016/j.neuroimage.2012.12.004
Ashley D. Harris, Muhammad G. Saleh, Richard A.E. Edden Edited 1H magnetic resonance spectroscopy in vivo: Methods and metabolites https://doi.org/10.1002/mrm.26619
The Gannet manual can be downloaded here - http://www.gabamrs.com/downloads
An example of the use of voxel segmentation is described here - DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332,
Analysis results of MEGA-PRESS with Gannet is shown in Figure 1 (Gannet Fit), Figure 2 (Gannet Output), Figure 3 (Gannet CoRegister), and Figure 4 (Gannet Segment) for the ACC brain region.
|-
|}
{|
|[[File:Figure 1.png|400px|thumb|left|Gannet Figure 1 ]]
|[[File:Figure2.png|400px|thumb|left|Gannet Figure 2 ]]
|[[File:Figure3.png|400px|thumb|left|Gannet Figure 3 ]]
|[[File:Figure4.png|400px|thumb|left|Gannet Figure 4 ]]
|}
==Location of data analysis results in Flywheel==
Note: For users using the CNI Optimized PRESS "nfl" sequence with LCModel data analysis -
Users who are in groups that are not themselves Flywheel "Lab" customers will need to download their results from the session tab now (not the analyses tab as was done before and shown in the figure below)
If you are using Google Chrome as the browser to download the processed data, then you will need to add the extension .zip to the downloaded file name. This operation does not not need to be done if using Safari or Firefox browsers.
MEGA-PRESS results will continue to be in the analyses tab.
[[Image:Screen Shot LCModel Session.png|1200px|thumb|center|LCModel Results]]


= Historical Information =
= Historical Information =


[[Historical Information]]
[[Historical Information]]

Latest revision as of 21:12, 26 August 2021

MRS in Neurosciences: In-vivo spectroscopy methods and applications at CNI

Overview

Discoveries about the brain have implications for fields ranging from Business, Law, Psychology, and Education. The interest of measuring metabolic changes via MRS techniques and combining that information with functional MRI measurements continues to grow. CNI continues to support the research of its user community by providing state-of-the art data acquisition and state-of-the-art data management and analysis capabilities for in-vivo spectroscopy. Through collaborative efforts the special interest spectroscopy group at CNI has enabled education, participated in experimental design, and guided analyses and interpretation of results.

Examples of studies at CNI using in-vivo spectroscopy techniques include characterization of biomarkers following transcranial magnetic stimulation, and metabolite characterization for conditions such as substance addiction, pain, depression, and various forms of dementia. These studies illustrate integrated data acquisition and data processing tools accessible to the CNI user community which simplify the use and sharing of spectroscopy results in neuroimaging applications.

Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332

The CNI continues to support the research of its user community by developing and incorporating for general use new data acquisition and data analysis capabilities.

GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691

Frequency drift in MR spectroscopy at 3T Hui et al. Frequency drift in MR spectroscopy at 3T https://doi.org/10.1016/j.neuroimage.2021.118430

Spectroscopy Websites and Literature

Websites:

An excellent spectroscopy resource website is https://mrshub.org/ The MRSHub is a curated collection of resources for the analysis of magnetic resonance spectroscopy data. It is maintained by the Committee for MRS Code and Data Sharing of the MR Spectroscopy Study Group of the International Society for Magnetic Resonance in Medicine (ISMRM).

To analyze the data from MEGA-PRESS experiments Gannet can be used. It is a batch-analysis tool for GABA-edited MRS data. The Gannet code and instruction manual can be downloaded from here http://www.gabamrs.com/


Books:

In Vivo NMR Spectroscopy, 2nd Edition, Author: Robin de Graaf, Wiley Online Library

The recently updated 3rd edition: In Vivo NMR Spectroscopy, 3rd Edition, Author: Robin de Graaf, Wiley Online Library

The 2014 book Magnetic Resonance Spectroscopy - Tools for Neuroscience Research and Emerging Clinical Applications


Papers:

A very comprehensive collection of MRS papers have been published in 2021 in a special issue of NMR in Biomedicine - Advanced methodology for in vivo magnetic resonance spectroscopy - https://doi.org/10.1002/nbm.4504

Key points abstracted from the Editorial page of this special issue are summarized here and the most relevant papers to the CNI spectroscopy tools are in bold type:

"For this Special Issue, these 13 topics of advanced methodology in clinical and pre-clinical MRS have been reviewed by multi-institutional groups of authors, and a consensus overview of the most relevant facts and recommendations has been assembled for each of them. They now appear along with proffered review papers from single or smaller groups of authors and proffered research papers with a broad range of topics covering latest research results."

"The consensus articles that lay out the current state of the art and present recommendations for use in terms of several aspects of advanced MRS were written by teams of prime experts in these fields, where the teams had been instructed to self-organize under consideration of the width of the field and respecting geographic and gender aspects. However, limiting the number of authors to a size that allows productive interchange, it was not possible to include all potential expert authors as based on their publication records. Thus, it was decided for many of the papers to include a larger group of experts as a collaborator group to receive input from and to cross-check and support the experts' recommendations. None of these papers that include “experts' consensus recommendations” in their titles are to be considered as typical white papers where traditionally detailed advice on exact measurement protocols and parameters is given. This had not been our intention because the topics covered are of an advanced nature and hence inherently still touch many work-in-progress frontiers. Furthermore, all topics covered still present challenges in terms of identifying overall optimal methods as approved by the community as a whole. In contrast, the recommendations in these papers were arrived at as a consensus opinion among the specific group of experts without claiming validity for the whole community, and also with the possibility to vary the weight of advice from hints to more strongly encouraged recommendations."

"The experts' consensus papers are targeted primarily at two types of readers: on one hand, the non-MRS-specialized MR physicist or high-end user (eg a clinician or neuroscientist) commissioned with the task of implementing state-of-the-art MRS methods for a specific research or clinical target that go beyond the vendor-provided MRS techniques; on the other hand, MRS specialists who try to grasp the background and current advances in topics with which they are not intimately familiar and to provide starting points to them when they consider incorporating them in their research or technical developments."

The 13 topics for the experts' consensus recommendation papers include two general papers followed by articles on specific topics in advanced MRS grouped in three fields of research.

*Two papers on the general background of methodology and publishing in MRS.

**Terminology and concepts in MRS Kreis R, Boer V, Choi IY, et al. Terminology and concepts for the characterization of in vivo MR spectroscopy methods and MR spectra: background and experts' consensus recommendations. NMR Biomed. 2020;e4347. https://doi.org/10.1002/nbm.4347 The first article of the special issue has the broad scope of presenting the basic framework of concepts and terminology in the field of in vivo MRS, which will hopefully help to standardize the language used and thus prevent misunderstandings in future publications in the field. It also contains suggestions for the use of abbreviations and provides references to the origin of concepts, methods and common abbreviations that at times appear without reference.

**Reporting standards Lin A, Andronesi O, Bogner W, et al. Minimum reporting standards for in vivo magnetic resonance spectroscopy (MRSinMRS): experts' consensus recommendations. NMR Biomed. 2021;e4484. https://doi.org/10.1002/nbm.4484 The second paper of a more general scope is concerned with minimal reporting guidelines for papers that include MRS data, whether published in MR literature or even more so in clinical journals. It has been a common experience for many of the experienced MRS methods experts to find essential details about employed MRS methods missing from published papers or in manuscripts submitted for review. Hence, Lin et al have assembled a list of items that the authors, who are all experienced referees, suggest should be covered in the methods section of future papers including MRS results. For ease of use, the paper also contains a checklist that could be submitted along with a manuscript as supplemental material or as a way to check that all vital information is provided in the methods section.

Checklist from https://doi.org/10.1002/nbm.4484

MRI system description

a. Field strength, eg 1.5 T, 3 T, 7 T, 9.4 T

b. Manufacturer, eg General Electric, Philips, Siemens, Toshiba

c. Model, eg General Electric Signa HD/X/T/de, Optima MR450/MR450W, Discovery MR750/MR750W, Signa Premier; Siemens Biograph mMR,Magnetom, Aera, Espree, Prisma, Skyra, Trio, Verio, Magnetom 7 T, Terra; Phillips Ingenia 1.5 T S, 3 T X/S, Elition 3 T X/S, Ambition 1.5 T X/S, Achieva 1.5 T/3 T. Software version, eg Siemens VB17A, VD19, VE11C; General Electric 12x-24x; Phillips Release 5, 5.1 (R1-3), 5.6, 6

d. RF coils used (nuclei, number of channels, type, body part), eg 1H, 31P, 13C, 31P-1H; type, eg head/neck, torso, knee; if not manufacturer, design, eg butterfly, quadrature etc

e. Additional hardware, eg shim inserts, dielectric pads


Acquisition parameters in full

i. Pulse sequence, eg spin-echo, point resolved spectroscopy (PRESS), stimulated echo acquisition mode (STEAM), semi-LASER, etc.

ii. Location of volume(s) of interest (VOI(s)), eg posterior cingulate gyrus, M. tibialis anterior, internal capsule of prostate, etc. A figure that displays the VOI on anatomic images is recommended.

iii. Nominal VOI size [cm3, mm3], eg 40 × 40 × 10 mm3.

iv. Repetition time (TR), echo time (TE) [ms, s]; if STEAM, mixing time (TM).

v. Total number of excitations per spectrum.

vi. Additional sequence parameters, eg

i. Spectral width [Hz, kHz] and number of data points

ii. Frequency offset (if any)

iii. If magnetic resonance spectroscopic imaging (MRSI): specification of two-dimensional (2D) or three-dimensional (3D) spatial mapping, field of view (FOV), matrix size, acceleration factor, sampling/reconstruction method (eg parallel imaging, compressed sensing, spatial spectral encoding, etc), nominal and effective (ie final) voxel volumes, flip angles for fast MRSI

iv. For multidimensional acquisitions, number of encodings in the second spectral dimension

v. For editing methods, editing pulse information including pulse shape, bandwidth and offset frequency

vi. For multinuclear sequences: details of decoupling or polarization transfer sequences and related parameters.


f. Water suppression method (and any other suppression methods used, eg lipid suppression, outer volume suppression).

g. Shimming method, reference peak used for assessing shim performance, and thresholds for “acceptance of shim” chosen.

h. Triggering method, if used (respiratory, peripheral, cardiac triggering, including device used and delays).

i. Frequency and motion correction methods, if used (prospective or retrospective, external tracker or navigator method).


Spectral quantification methods and parameters

a. Software package used to reconstruct and analyze the MRS data including MR manufacture software (eg General Electric PROBE, Siemens Syngo, or Phillips SpectroView) and/or third-party software packages (eg LCModel, jMRUI, TARQUIN, SIVIC, INSPECTOR, FID-A, BrainSpec, MIDAS, GANNET)

b. Deviations in processing steps from quoted reference or product defaults

c. Quantitative output measures

d. Quantification references and assumptions, model fitting assumptions


Quality assurance. Studies must include the following

a. Reported variables (SNR, linewidth, and description of how they were obtained)

b. Data exclusion criteria

c. Other quality measures from fitting software are also recommended (eg standard deviation (SD), Cramér-Rao lower bound (CRLB)), and/or the robustness of the measures gained (repeatability measures if known)

d. Figure showing representative spectra


*Four papers dealing with commonly used MRS acquisition sequences and processing methods.

**Advanced single-voxel MRS Oz G, Deelchand DK, Wijnen JP, et al. Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: experts' consensus recommendations. NMR Biomed. 2020;e4236. https://doi.org/10.1002/nbm.4236

**Advanced neuro-MRSI Maudsley AA, Andronesi OC, Barker PB, et al. Advanced magnetic resonance spectroscopic neuroimaging: experts' consensus recommendations. NMR Biomed. 2020;e4309. https://doi.org/10.1002/nbm.4309

**Spectral editing Choi IY, Andronesi OC, Barker P, et al. Spectral editing in 1H magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4411. https://doi.org/10.1002/nbm.4411

**Processing and quantification Near J, Harris AD, Juchem C, et al. Preprocessing, analysis and quantification in single-voxel magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4257. https://doi.org/10.1002/nbm.4257


  • Three papers related to MRS techniques that are critical to ensure the quality of data.
    • Water and lipid suppression Tkac I, Deelchand D, Dreher W, et al. Water and lipid suppression techniques for advanced 1H MRS and MRSI of the human brain: experts' consensus recommendations. NMR Biomed. 2020;e4459. https://doi.org/10.1002/nbm.4459
    • B0 shimming Juchem C, Cudalbu C, de Graaf RA, et al. B0 shimming for in vivo magnetic resonance spectroscopy: experts' consensus recommendations. NMR Biomed. 2020;e4350. https://doi.org/10.1002/nbm.4350
    • Motion correction Andronesi OC, Bhattacharyya PK, Bogner W, et al. Motion correction methods for MRS: experts' consensus recommendations. NMR Biomed. 2020;e4364. https://doi.org/10.1002/nbm.4364


  • Four papers appertaining to special targets of MRS studies.
    • Macromolecular signals and ways to accommodate them in1H MR brain spectra Cudalbu C, Behar KL, Bhattacharyya PK, et al. Contribution of macromolecules to brain 1H MR spectra: experts' consensus recommendations. NMR Biomed. 2020;e4393. https://doi.org/10.1002/nbm.4393
    • 1H MRS of skeletal muscle Krssak M, Lindeboom L, Schrauwen-Hinderling V, et al. Proton magnetic resonance spectroscopy in skeletal muscle: experts' consensus recommendations. NMR Biomed. 2020;e4266. https://doi.org/10.1002/nbm.4266
    • 31P MRS of skeletal muscle Meyerspeer M, Boesch C, Cameron D, et al. 31P magnetic resonance spectroscopy in skeletal muscle: experts' consensus recommendations. NMR Biomed. 2020;e4246. https://doi.org/10.1002/nbm.4246
    • Specifics for MRS methods in preclinical applications Lanz B, Abaei A, Braissant O, et al. Magnetic resonance spectroscopy in the rodent brain: experts' consensus recommendations. NMR Biomed. 2020;e4325. https://doi.org/10.1002/nbm.4325


  • This special issue also includes authoritative reviews of the current state of
    • fast MRSI methodology Bogner W, Otazo R, Henning A. Accelerated MR spectroscopic imaging—a review of current and emerging techniques. NMR Biomed. 2020;e4314. https://doi.org/10.1002/nbm.4314
    • hyperpolarized 13C MRI and MRS Crane JC, Gordon JW, Chen H-Y, et al. Hyperpolarized 13C MRI data acquisition and analysis in prostate and brain at University of California, San Francisco. NMR Biomed. 2020;e4280. https://doi.org/10.1002/nbm.4280


  • Fifteen proferred original research contributions complete this special issue. They cover latest research results in terms of novel advanced MRS methodology or its application. The methodology addresses issues in

**standardization - Deelchand DK, Berrington A, Noeske R, et al. Across-vendor standardization of semi-LASER for single-voxel MRS at 3T. NMR Biomed. 2019;e4218. https://doi.org/10.1002/nbm.4218

    • diffusion MRS Lundell H, Ingo C, Dyrby TB, Ronen I. Cytosolic diffusivity and microscopic anisotropy of N-acetyl aspartate in human white matter with diffusion-weighted MRS at 7 T. NMR Biomed. 2020;e4304. https://doi.org/10.1002/nbm.4304 Hanstock C, Beaulieu C. Rapid acquisition diffusion MR spectroscopy of metabolites in human brain. NMR Biomed. 2020;e4270. https://doi.org/10.1002/nbm.4270 Genovese G, Marjańska M, Auerbach EJ, et al. In vivo diffusion-weighted MRS using semi-LASER in the human brain at 3 T: methodological aspects and clinical feasibility. NMR Biomed. 2020;e4206. https://doi.org/10.1002/nbm.4206
    • editing Deelchand DK, Marjańska M, Henry P-G, Terpstra M. MEGA-PRESS of GABA+: influences of acquisition parameters. NMR Biomed. 2019;e4199. https://doi.org/10.1002/nbm.4199 Ma RE, Murdoch JB, Bogner W, Andronesi O, Dydak U. Atlas-based GABA mapping with 3D MEGA-MRSI: cross-correlation to single-voxel MRS. NMR Biomed. 2020;e4275. https://doi.org/10.1002/nbm.4275 Bell T, Boudes ES, Loo RS, et al. In vivo Glx and Glu measurements from GABA-edited MRS at 3 T. NMR Biomed. 2020;e4245. https://doi.org/10.1002/nbm.4245
    • novel acquisition techniques Kulpanovich A, Tal A. What is the optimal schedule for multiparametric MRS? A magnetic resonance fingerprinting perspective. NMR Biomed. 2019;e4196. https://doi.org/10.1002/nbm.4196 Posse S, Sa De La Rocque Guimaraes B, Hutchins-Delgado T, et al. On the acquisition of the water signal during water suppression: high-speed MR spectroscopic imaging with water referencing and concurrent functional MRI. NMR Biomed. 2020;e4261. https://doi.org/10.1002/nbm.4261
    • processing techniques Francischello R, Geppi M, Flori A, Vasini EM, Sykora S, Menichetti L. Application of low-rank approximation using truncated singular value decomposition for noise reduction in hyperpolarized 13C NMR spectroscopy. NMR Biomed. 2020;e4285. https://doi.org/10.1002/nbm.4285 Marjańska M, Terpstra M. Influence of fitting approaches in LCModel on MRS quantification focusing on age-specific macromolecules and the spline baseline. NMR Biomed. 2019;e4197. https://doi.org/10.1002/nbm.4197 Landheer K, Swanberg KM, Juchem C. Magnetic resonance Spectrum simulator (MARSS), a novel software package for fast and computationally efficient basis set simulation. NMR Biomed. 2019;e4129. https://doi.org/10.1002/nbm.4129
    • reported applications probe the feasibility of novel uses of advanced MRS methods van Houtum Q, Mohamed Hoesein FAA, Verhoeff JJC, et al. Feasibility of 31P spectroscopic imaging at 7 T in lung carcinoma patients. NMR Biomed. 2019;e4204. https://doi.org/10.1002/nbm.4204 Rioux JA, Hewlett M, Davis C, et al. Mapping of fatty acid composition with free-breathing MR spectroscopic imaging and compressed sensing. NMR Biomed. 2019;e4241. https://doi.org/10.1002/nbm.4241 Peeters TH, van Uden MJ, Rijpma A, Scheenen TWJ, Heerschap A. 3D 31P MR spectroscopic imaging of the human brain at 3 T with a 31P receive array: an assessment of 1H decoupling, T1 relaxation times, 1H-31P nuclear Overhauser effects and NAD+. NMR Biomed. 2019;e4169. https://doi.org/10.1002/nbm.4169



Several new publications here on advanced editing techniques - http://www.gabamrs.com/


Voxel placement publication

AutoVOI: real‐time automatic prescription of volume‐of‐interest for single voxel spectroscopy Young Woo Park Dinesh K. Deelchand James M. Joers Brian Hanna Adam Berrington Joseph S. Gillen Kejal Kantarci Brian J.Soher Peter B. Barker HyunWook Park Gülin Öz Christophe Lenglet Magn Reson MEd. 2018;80:1787-1798 https://doi.org/10.1002/mrm.27203


New open-source processing package currently under evaluation -

Osprey: Open-source processing, reconstruction & estimation of magnetic resonance spectroscopy data Georg Oeltzschner Helge J.Zöllner Steve C.N.Hui Mark Mikkelsen Muhammad G.Saleh Sofie Tapper Richard A.E. Edden Journal of Neuroscience Methods Volume 343, 1 September 2020, 108827 https://doi.org/10.1016/j.jneumeth.2020.108827


Presentation at 2020 ENC Meeting - Accelerated MR spectroscopic imaging—a review of current and emerging techniques

Accelerated MR spectroscopic imaging—a review of current and emerging techniques Wolfgang Bogner Ricardo Otazo Anke Henning NMR in Biomedicine.2020;e4314 https://doi.org/10.1002/nbm.4314

Spectroscopy Data Acquisition Tools at CNI

Spectroscopy Sequences

The Stanford CNI effort has become a best practice through a community effort with spectroscopy expertise from CNI staff, MRI scientists, and an expanding user community. Current spectroscopy sequences include methods both for edited GABA (gamma-Aminobutyric acid) specific data acquisition (MEGA-PRESS [1] and IM-SPECIAL [3]), and for multi-metabolite data acquisition (Optimized-PRESS [4], [5], [6]) and semi-LASER [9], [10], [11], [12], [13] Most sequences are linked to automatic processing pipelines in CNI's data management system, Flywheel, as referenced in the table below.


Spectroscopy Sequence Measured Metabolites Analysis Methods
MEGA-PRESS [1] GABA+, Glx(Glutamate, Glutmine) Gannet [2]
IM-SPECIAL [3] GABA, Glu(Glutamate), Glx(Glutamate, Glutamine) Sequence specific Matlab code
Optimized-PRESS [4], [5], [6] All metabolites LCModel fitting [7]
semi-LASER [9], [10], [11], [12], [13] All metabolites LCModel fitting [7]


References

[1] Mescher M, Merkle H, Kirsch J, Garwood M, Gruetter R (1998) Simultaneous in vivo spectral editing and water suppression, NMR Biomed. 11:266–272 https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291099-1492%28199810%2911%3A6%3C266%3A%3AAID-NBM530%3E3.0.CO%3B2-J

[2] Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris, Peter B. Barker, and C. John Evans (2014) Gannet: A Batch-Processing Tool for the Quantitative Analysis of Gamma-Aminobutyric Acid–Edited MR Spectroscopy Spectra, Journal of Magnetic Resonance Imaging 40:1445–1452 https://doi.org/10.1002/jmri.24478

[3] Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691

[4] Webb PG, Sailasuta N, Kohler SJ, Raidy T, Moats RA, Hurd R (1994) Automated single voxel proton MRS: technical development and multisite verification, Magnetic Resonance in Medicine 31(4):365-373 https://doi.org/10.1002/mrm.1910310404

[5] Bodenhausen G, Freeman R, Turner DL (1977) Suppression of artifacts in two dimensional J spectroscopy, Journal of Magnetic Resonance Imaging 27:511-514 https://doi.org/10.1016/0022-2364(77)90016-6

[6] Tran TK, Vigneron DB, Sailasuta N, Tropp J, Le Roux P, Kurhanewicz J, Nelson S, Hurd R (2000) Very selective suppression pulses for clinical MRSI studies of brain and prostate cancer, Magnetic Resonance in Medicine 43(1):23-33. https://onlinelibrary.wiley.com/doi/abs/10.1002/%28SICI%291522-2594%28200001%2943%3A1%3C23%3A%3AAID-MRM4%3E3.0.CO%3B2-E

[7] Provencher SW (2001) Automatic quantitation of localized in vivo1H spectra with LCModel, NMR in Biomedicine 14(4):260-264 https://doi.org/10.1002/nbm.698

[8] Young Woo Park, Dinesh K. Deelchand, James M. Joers, Brian Hanna, Adam Berrington, Joseph S. Gillen, Kejal Kantarci, Brian J. Soher, Peter B. Barker, HyunWook Park, Gulin Oz, Christophe Lenglet (2018) AutoVOI: real-time automatic prescription of volume-of-interest for single voxel spectroscopy, Magn. Reson. Med. 80:1787–1798 https://doi.org/10.1002/mrm.27203

[9] Scheenen TWJ, Klomp DWJ, Wijnen JP, Heerschap A. (2018) Short echo time 1H-MRSI of the human brain at 3T with minimal chemical shift displacement errors using adiabatic refocusing pulses, Magn. Reson. Med. 59(1):1-6 https://doi.org/10.1002/mrm.21302

[10] Oz G, Tkac I. (2011) Short-echo, single-shot, full-intensity proton magnetic resonance spectroscopy for neurochemical profiling at 4 T: validation in the cerebellum and brainstem, Magn. Reson. Med. 65(4):901-910 https://doi.org/10.1002/mrm.22708

[11] Martin Wilson, Ovidiu Andronesi, Peter B. Barker, Robert Bartha, Alberto Bizzi, Patrick J. Bolan, Kevin M. Brindle, In-Young Choi, Cristina Cudalbu, Ulrike Dydak, Uzay E. Emir, Ramon G. Gonzalez, Stephan Gruber, Rolf Gruetter, Rakesh K. Gupta, Arend Heerschap, Anke Henning,Hoby P. Hetherington, Petra S. Huppi, Ralph E. Hurd, Kejal Kantarci, Risto A Kauppinen, Dennis W. J. Klomp, Roland Kreis, Marijn J. Kruiskamp, Martin O. Leach, Alexander P. Lin, Peter R. Luijten, Malgorzata Marjanska, Andrew A. Maudsley, Dieter J. Meyerhoff, Carolyn E. Mountford, Paul G. Mullins, James B. Murdoch, Sarah J. Nelson, Ralph Noeske, Gulin Oz, Julie W. Pan, Andrew C. Peet, Harish Poptani, Stefan Posse, Eva-Maria Ratai, Nouha Salibi, Tom W. J. Scheenen, Ian C. P. Smith, Brian J. Soher, Ivan Tkac, Daniel B. Vigneron, Franklyn A. Howe (2019) Methodological consensus on clinical proton MRS of the brain:Review and recommendations, Magn. Reson. Med. 82:527–550 https://doi.org/10.1002/mrm.27742

[12] Dinesh K. Deelchand, Adam Berrington, Ralph Noeske, James M. Joers, Arvin Arani, Joseph Gillen, Michael Schar, Jon-Fredrik Nielsen, Scott Peltier, Navid Seraji-Bozorgzad, Karl Landheer, Christoph Juchem, Brian Soher, Douglas C. Noll, Kejal Kantarci, Eva M. Ratai, Thomas H. Marecii, Peter B. Barker, Gulin Oz (2019) Across-vendor standardization of semi-LASER for single-voxel MRS at 3T, NMR in Biomedicine. e4218 https://doi.org/10.1002/nbm.4218

[13] Gulin Oz, Dinesh K. Deelchand, Jannie P. Wijnen, Vladimir Mlynarik, Lijing Xin, Ralf Mekle, Ralph Noeske, Tom W.J. Scheenen, Ivan Tkac, the Experts' Working Group on Advanced Single Voxel 1H MRS (2020) Advanced single voxel 1H magnetic resonance spectroscopy techniques in humans: Experts' consensus recommendations, NMR in Biomedicine. e4236 https://doi.org/10.1002/nbm.4236

Current CNI spectroscopy protocols

There are two CNI spectroscopy protocols

(1) The protocol spectro-protocol-1 located in the CNI "Other" tab on the scanner has the sLaser and optimized-PRESS sequences for data collection for all metabolites. For new studies users should use the sLaser sequence. For longitudinal studies the optimized-PRESS sequence can be continued to be used.

(2) The protocol spectro-protocol-1 - editing located in the CNI "Other" tab on the scanner has the MEGA-PRESS sequence for data collection for GABA.


(1) Protocol screen shot: Spectro-protocol-1

spectro-protocol-1
spectro-protocol-1
Spectroscopy Sequence Description and General Information Parameters for Publications corresponding to the GE CV's of those parameters
Localizer
T1 High Resolution T1 with automatic reformatting for sagittal, coronal, and axial views.
T2
Voxel Placement Sequence for rotated voxel placement (details described in separate section further below)
s-Laser This sequence is the GE "Works in Progress" and is consistent with the ISMRM Experts' consensus recommendations for this sequence."High field (3T) and ultra-high field (7T) are ideal field strength for MR spectroscopy due to the higher spectral resolution and higher signal that can be achieved. But with these advantages comes a higher B1-inhomogeneity and larger Chemical Shift Displacement Error (CSDE). Semi-LASER is a double spin-echo MRS technique like the established PRESS (GE product name Probe-P) technique that uses a slice selective non-adiabatic excitation and two pairs of adiabatic slice selective refocusing pulses for volume selection. The adiabatic behavior of the RF pulses addresses the B1-inhomogeneity problem while the increased bandwidth of these pulses reduces the CSDE."
Optimized-PRESS This sequence is a GE "Works in Progress" and is consistent with the ISMRM Experts' consensus recommendations for this sequence. This is currently considered a legacy sequence.



Screen shots of parameters and CV's for s-laser sequence

Figure 1 s-Laser
Figure 2 s-Laser
Figure 3 s-Laser

Screen shots of parameters and CV's for optimized-press sequence

Figure 1 optimized-press
Figure 2 optimized-press
Figure 3 optimized-press



(2) Protocol screen shot:Spectro-protocol-editing-1

spectro-editing-protocol-1
spectro-editing-protocol-1
Spectroscopy Sequence Description and General Information Parameters for Publications corresponding to the GE CV's of those parameters
Localizer
T1 High Resolution T1 with automatic reformatting for sagittal, coronal, and axial views.
T2
Voxel Placement Sequence for rotated voxel placement (details described in separate section further below)
MEGA-PRESS The current spectroscopy sequence for edited GABA (gamma-Aminobutyric acid) data acquisition is MEGA-PRESS. This sequence is the GE "Works in Progress" (Rx28) and is consistent with the ISMRM Experts' consensus recommendations for this sequence. The only modification of the CNI version from the GE Works in progress is the value of TR (CNI TR = 2000, changed from TR = 1800)

MEGA-PRESS description for publications - Example MEGA-PRESS description for publication from Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332, Additional example sequence description from GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence Gu M, Hurd R, Noeske R, Baltusis L, Hancock R, Sacchet MD, Gotlib IH, Chin FT, Spielman DM (2018) GABA editing with macromolecule suppression using an improved MEGA-SPECIAL sequence, Magnetic Resonance in Medicine 79:41-47 https://doi.org/10.1002/mrm.26691

Screen shots of the current MEGA-PRESS sequence are shown below. Figures 1-3 display all parameters and CV's. With this sequence the spectra are processed automatically and stored (Figure 4). The data can be inspected via the GE scanner data viewer (Figure 5).

MRI system description
  • MRI scanning sessions were completed at the Stanford Center for Cognitive and Neurobiological Imaging. Images were acquired using a 3T GE Discovery UHP MR scanner and 32-channel Nova head coil.

Acquisition parameters

  • For each participant, high-resolution T1-weighted 3D Bravo sagittal scans (1.0 mm3 voxels) were acquired towards the start of the scanning session and used for accurate placement of the MRS voxels.
  • Single voxel in-vivo 1H MRS scans were acquired using a MEGA-PRESS sequence (Mescher et al. 1998)
  • editing pulses: 14 ms 180° Gaussian-weighted sinc pulses (CV19, CV22)
  • applied at 1.9/7.5 ppm (CV20, CV21)
  • with TE/TR = 68 ms/2000 ms, respectively
  • Volumes were shimmed at the start of each MRS scan.
  • The GABA editing was performed on a 20 x 20 x 20 mm voxel
  • 128 transients were acquired (CV4)
  • with a scan time of 9 min 20 s

Screen shots of parameters and CV's for MEGA-PRESS sequence

Figure 1 MEGA-PRESS
Figure 2 MEGA-PRESS
Figure 3 MEGA-PRESS


Figure 4 MEGA-PRESS
Figure 5 MEGA-PRESS

Prescribing a rotated voxel

At the moment GE’s DV26 and higher software platforms release doesn’t support voxel rotation for spectroscopy sequences. A workaround however is available:

(1) After the 3-plane reconstruction of the T1w images, setup a 3D imaging scan. We saved a template of this 3D scan in the protocol “CNI Example Spectroscopy” and named it as “Voxel prescription”. Add this sequence to your protocol and put it before the MRS scan.

(2) Setup the voxel prescription scan. The Scan Plane is set to “Oblique”, FOV and Locs per Slab are set as close to the voxel size of the spectro scan as possible. Prescribe the 3D box, place it to the desired location and rotate to the right angle. Because the box is usually bigger than the voxel size you want to prescribe, the coverage you see in this step is not accurate. It’s crucial to get the correct orientation of the box. Save Rx.

(3) Setup the MRS scan. Copy Rx from the voxel prescription scan. By default the Mode Filter in the Copy Rx is set to “MRS”, you need to change it to “All” or “3D” in order to see the voxel prescription scan in the Copy Rx list. Select it and accept.

(4) Adjust voxel location and size. You can move the box around and change its size on the graphic interface, or set its coordinates and size by setting the Center and Length in X, Y, Z. If you want to adjust the orientation of the voxel, you need to go back to the 3D voxel prescription scan, and repeat step 2-4 again. After you finish setting up the MRS scan, Save Rx and proceed with scanning.

Extracting voxel prescription information retrospectively

The prescription information of the voxel of an MRS scan is saved in the header of the raw data (p-file). Specifically, the x, y, z dimensions of the voxel are stored in header fields rdb_hdr_image.user8, rdb_hdr_image.user9, rdb_hdr_image.user10; the x, y, z locations of the center of the voxel are stored in header fields rdb_hdr_image.user11, rdb_hdr_image.user12, rdb_hdr_image.user13, in RAS coordinates (e.g. if the voxel is at L26.0 then rdb_hdr_image.user11 will record -26.0). The unit is mm.

To look for this information on Flywheel, open the information window of the p-file, and search for op_user_8, op_user_9, op_user_10, etc.

Spectroscopy Data Processing Tools at CNI

Data Management

CNI currently uses Flywheel as its data base management system. A critical feature of this data base management is the ability to share computational methods within the system. The CNI now provides a combination of data repository and integrated open source processing tools such as Gannet [2] and LCModel [7]. This combination of tools supports scientific transparency for both data and computational sharing. Spectroscopy analysis methods such as LCModel can be containerized as a gear in Flywheel for automated processing and data visualization.


Flywheel

Current CNI spectroscopy Flywheel gears

Each of the supported spectroscopy sequences is linked to a Flywheel gear for automatic data processing

Spectroscopy Sequence Measured Metabolites Analysis Methods
semi-Laser All metabolites Sequence specific Matlab code, LCModel fitting - Flywheel processing gear placeholder information here: LCMODEL_r_dlpfc_nfl_[BASIS_SET=02_01_19,FIXED_NAA=0]_(2021-05-13)
Optimmized_PRESS All metabolites Sequence specific Matlab code, LCModel fitting - Flywheel processing gear placeholder information here: LCMODEL_r_dlpfc_nfl_[BASIS_SET=02_01_19,FIXED_NAA=0]_(2021-05-13)
MEGA-PRESS GABA+, Glx(Glutamate, Glutmine) To analyze the data from MEGA-PRESS experiments, we recommend Gannet, a batch-analysis tool for GABA-edited MRS data http://www.gabamrs.com/. Currently the latest version 3.1 is Docker containerized. This needs to be manually run, but this analysis method will soon be changed to a Flywheel gear for automatic analysis and storage of results (see location of data analysis results section below).

References from the Gannet web site include:

Richard A.E. Edden, Nicolaas A.J. Puts, Ashley D. Harris, Peter B. Barker, and C. John Evans (2014) Gannet: A Batch-Processing Tool for the Quantitative Analysis of Gamma-Aminobutyric Acid–Edited MR Spectroscopy Spectra, Journal of Magnetic Resonance Imaging 40:1445–1452 https://doi.org/10.1002/jmri.24478

Paul G.Mullins David J.McGonigle Ruth L.O'Gorman Nicolaas A.J.Puts RishmaVidyasagar C. JohnEvans Cardiff Symposium on MRS of GABA Richard A.E.Edden Current practice in the use of MEGA-PRESS spectroscopy for the detection of GABA https://doi.org/10.1016/j.neuroimage.2012.12.004

Ashley D. Harris, Muhammad G. Saleh, Richard A.E. Edden Edited 1H magnetic resonance spectroscopy in vivo: Methods and metabolites https://doi.org/10.1002/mrm.26619

The Gannet manual can be downloaded here - http://www.gabamrs.com/downloads

An example of the use of voxel segmentation is described here - DeSouza DD, Stimpson K, Baltusis L, Sacchet MD, Gu M, Hurd R, Wu H, Yeomans DC, Williams N, Spiegel D. Association between anterior cingulate neurochemical concentration and individual differences in hypnotizability. Cerebral Cortex, Volume 30, Issue 6, June 2020, Pages 3644–3654, https://doi.org/10.1093/cercor/bhz332,

Analysis results of MEGA-PRESS with Gannet is shown in Figure 1 (Gannet Fit), Figure 2 (Gannet Output), Figure 3 (Gannet CoRegister), and Figure 4 (Gannet Segment) for the ACC brain region.

Gannet Figure 1
Gannet Figure 2
Gannet Figure 3
Gannet Figure 4

Location of data analysis results in Flywheel

Note: For users using the CNI Optimized PRESS "nfl" sequence with LCModel data analysis - Users who are in groups that are not themselves Flywheel "Lab" customers will need to download their results from the session tab now (not the analyses tab as was done before and shown in the figure below)

If you are using Google Chrome as the browser to download the processed data, then you will need to add the extension .zip to the downloaded file name. This operation does not not need to be done if using Safari or Firefox browsers.

MEGA-PRESS results will continue to be in the analyses tab.


LCModel Results

Historical Information