June, 2011

CNI update

From: bobd at stanford.edu (Robert Dougherty)
Date: Tue, 07 Jun 2011 11:38:21 -0700
Subject: [cni-mrusers] CNI update

Hi All,

Just a little update on how things are going down here at the CNI MR facility.

1. We finally got our signage approved and installed on the wall next to our main entrance! This should make it easier for scan subjects to find us. (And yes, we think the colon looks silly too.)

2. The mock scanner is ready for use. We had a double mirror built for it, so the display system is now a nice replica of the real scanner. Thanks to Kalanit and Alina for helping us get it up and running.

3. The 8-channel coil now also has a double-mirror like the one in the 32-channel coil, so stimuli viewed through it are properly oriented.

4. The prototype of the bone-conduction auditory system is working and several researchers are using it to present auditory stimuli in the 32-channel coil. We are working on an improved version with a more comfortable and easier to use form-factor, but that will probably take several months to develop and install. If you want to use the current system, please contact me and I'll show you how to set it up.

5. We now have the scan triggering sorted out in what we think is a cleaner, more organized system. Note that the "Serial Trigger" device has been updated and is now labelled "Eprime trigger". This device can also be used to receive the timing pulses in from the scanner, if you need those. You might need to install a new driver to use the new device. The old serial trigger device is still available for use (labelled "Defunct serial trigger"), but we hope to remove it soon, so please update your drivers to use the new trigger device. See the wiki http://cniweb.stanford.edu/wiki/MR_Hardware#Scan_Triggers) for details, and don't hesitate to ask us for help in getting your triggering sorted out.

6. We finished building a device needed for EEG balistocardiogram artifact removal. This is based on Gary Glover's idea of using the PPG (pulse oximetry) rather than ECG leads. Let us know if you'd like to do EEG and we can give you a tour of the system.

7. Reno has completed and installed a new version of the automated data transfer system. We call it "MR Steward". MR Steward in now more stable and reliable than the previous versions, and adds a couple of nice new features. As in the previous version, it automatically copies your DICOM files and P-files to the Linux box to the right of the console and generates NIFTI files for you. It now also finds and copies physiological data that you might have recorded and puts it in the same directory as your other data. Finally, it automatically starts the recon for any P-files produced by Atsushi's spiral PSD. This should all happen while you scan, so that your data should be available soon after you finish scanning.

8. Finally, Atsushi has make several nice improvements to the cni_epi pulse sequence. Details on this will follow in a separate email. We encourage everyone doing BOLD EPI to ensure that they are using this PSD. (Contact me or Atsushi for help.)

cheers, bob


Robert F. Dougherty, PhD 
Research Director
Stanford Center for Cognitive and Neurobiological Imaging
70 Jordan Hall * Stanford CA 94305 * 650-725-0051
http://www.stanford.edu/~bobd

BOLD EPI PSD update

From: bobd at stanford.edu (Robert Dougherty)
Date: Tue, 07 Jun 2011 12:35:14 -0700
Subject: [cni-mrusers] BOLD EPI PSD update

Hi All,

Atsushi has just completed testing an updated BOLD EPI PSD. It is now 
installed on our scanner as "cni_epi". The basic imaging functionality 
is the same as with previous versions of our EPI psd, however Atsushi 
has made several important improvements around the edges.

1. The 10,000 image limit has been removed. You can now set up scans to 
run for as long as you like!

2. ASSET acceleration limits have been removed. Acceleration was 
previously locked to only two options: 1 (no acceleration), or 2. You 
can now set the ASSET acceleration factor to just about anything that 
you like, including fractional values, like 1.5.

3. There are now several new UserCVs under the "Advanced" tab:

* Scope trigger: This controls the timing pulses that come out of the 
scanner through the "scope trigger" connection. These pulses can be 
captured by our serial port trigger device and used to record the exact 
timing of each slice (set this CV to 0) or each volume (set this CV to 
1). See the wiki 
(http://cniweb.stanford.edu/wiki/MR_Hardware#Capturing_scan_timing_triggers) 
for details on capturing these pulses.

* Reconstruct image at native resolution: This CV allows you to force 
the image reconstruction to occur at the acquired matrix size (set this 
CV to 1) rather than at the next higher power of two. E.g., if you set a 
matrix size of 74, the image is reconned at 74x74 rather than 
interpolated up to 128x128. This makes for faster recons and smaller 
files, and avoids confusion about "effective resolution" vs. the image 
voxel size. This is now the default behavior! If you liked your images 
to be interpolated up to the next higher power of two, you can set this 
CV to 0 to get that old behavior back.

* Save physio data: If you have connected the PPG, respiration belt, 
and/or ECG leads to your scan subject and want to save the data that are 
measured, set this to 1. Reno's MR Steward data transfer system should 
automatically find and transfer the physio files for you. However, this 
new feature of MR Steward is experimental. If you think that you saved 
physio data but can't find it, let us know and we'll help you get it out.

The start scan trigger CV is still there and functions as before, 
allowing no trigger (0), external triggering (1), or cardiac gating (2).

Please make sure that your BOLD EPI protocol uses this new PSD. If you 
are unsure of how to check this, just let us know and we can have a look 
with you.

We don't expect this update to interfere with any ongoing studies. The 
core imaging logic has not been touched, so images acquired with this 
new PSD should be the same as before. The only change that you might 
notice is that the resulting image size is no longer interpolated to the 
next power of two. If you think this might cause problems for your 
analysis pipeline, be sure to change this new CV to 0 to get the old 
behavior back.

cheers,
bob

-- 
Robert F. Dougherty, PhD
Research Director
Stanford Center for Cognitive and Neurobiological Imaging
70 Jordan Hall  *  Stanford CA 94305  *  650-725-0051
http://www.stanford.edu/~bobd

May, 2011

Sound delivery for the 32-channel coil

From: bobd at stanford.edu (Robert Dougherty)
Date: Wed May 11 21:25:16 PDT 2011
Subject: [cni-mrusers] Sound delivery for the 32-channel coil

For those interested in presenting auditory stimuli at the CNI, please 
read on.

As many of you know, the Resonance Tech headphones that are currently 
installed at the CNI do not fit comfortably in the 32-channel head coil 
for many subjects. We are currently testing a prototype system that will 
fit in this coil. It uses MR-safe piezoelectric transducers (kindly 
provided by Resonance Tech.), that are identical to the ones used in our 
current headphones. But instead of conducting sound via air, these 
transducers are pressed against the subject's cheeks and conduct sound 
via direct bone conduction. The transducers are very thin and thus 
easily fit in the 32-channel coil.

I just finished a pilot test, and the sound quality was good; 
speech-range stimuli were clearly audible during all our typical fMRI 
scan sequences (EPI and spiral), as well as the anatomical sequences. 
The main issue to be worked out is consistent positioning of the 
transducers to deliver clear sound while maintaining subject comfort. I 
think the best way to learn how to do this is to come down and try it 
out on yourself! I can show you what I did to get it working for me.

So, if you want to present auditory stimuli in the 32-channel coil, let 
me know when you can come by to see the new system.

cheers,
bob

-- 
Robert F. Dougherty, PhD
Research Director
Stanford Center for Cognitive and Neurobiological Imaging
70 Jordan Hall  *  Stanford CA 94305  *  650-725-0051
http://www.stanford.edu/~bobd

April, 2011

Flat panel display out for repairs

From: bobd at stanford.edu (Robert Dougherty)
Date: Thu Apr 7 17:24:11 PDT 2011
Subject: [cni-mrusers] Flat panel display out for repairs...

Hi All,

The flat panel display that sits at the back of the bore will be going 
out for repairs tomorrow (4/8) at 11am. It will be back in place by 10am 
Wednesday (4/13) morning. The goggle system will be available for visual 
stimuli during this time.

When the display returns next Wednesday, the sticky power button issue 
will be fixed and we will be able to adjust the display to make it 
brighter (it is currently stuck at its lowest brightness setting). We 
will also be able to move the display closer to the bore for a larger 
field of view. We'll mark the current position so if you can keep the 
viewing distance the same as it is now if you like.

Also, I'd like to you all know that we are planning to remove the 
current mirror-reversal that subjects experience while viewing the flat 
panel display through the single mirror by switching to a dual-mirror 
and mounting the display upside-down. This will happen in about two 
weeks. (I will send another note next week with a more specific date for 
the switch.) I apologize to those who have already adapted their 
stimulus display software to the current configuration by left-right 
flipping your stimuli-- you will have to undo this in your software 
after we implement the new configuration. This new arrangement will fix 
the mirror-reversal in a way that is compatible with all stimulus 
display packages.

thanks,
bob

-- 
Robert F. Dougherty, PhD
Research Director
Stanford Center for Cognitive and Neurobiological Imaging
70 Jordan Hall  *  Stanford CA 94305  *  650-725-0051
http://www.stanford.edu/~bobd

LCD display, bite bar

From: bobd at stanford.edu (Robert Dougherty)
Date: Mon Apr 25 22:06:25 PDT 2011
Subject: [cni-mrusers] LCD display, bite bar

Hi All,

There have been a couple of recent improvements at the CNI:

1. The 32 channel coil now has a bite bar holder. It's same design as 
the one on the 8-channel (see the wiki: 
http://cniweb.stanford.edu/wiki/MR_Peripherals#Subject_Positioning). We 
have several mouth-pieces that can be used in either holder (see me for 
details). We don't yet have a supply of dental wax at the CNI, so bring 
your own if you need to use the bite bar.

2. The LCD display is now mounted upside-down. No, Gunnar and I didn't 
just screw up when re-mounting it. This, coupled with the new 
double-mirror on the 32-channel coil, means that images presented on the 
screen are no longer mirror reversed. Stimuli will appear to the subject 
exactly as they appear to you looking at the stimulus display monitor in 
the control room. Double-mirrors for the 8-channel coil and the 
16-channel visual array are currently being built an should be in place 
by next week. See me if you need a mirror solution for these coils 
before then. Note that the mirrors are first-surface, which means that 
the reflected images are very nice, but also means that the mirror 
coating is exposed and more fragile than a standard (rear-surface) 
mirror. Please use care when cleaning them. There is a box of lens 
cleaners in the scan room near the positioning pads.

3. The LCD display has been been fixed so that it no longer needs to be 
power-cycled to wake up from sleep mode. Just turn it on once when you 
arrive and it should wake up whenever a video signal is sent.

4. There is a new response device available for use. It's a 4-button 
cylinder. See the wiki 
(http://cniweb.stanford.edu/wiki/MR_Peripherals#Response_Box) for 
details. Ask me if you need help using this or any of the other response 
devices.

5. We now have two scan trigger methods installed. See the wiki 
(http://cniweb.stanford.edu/wiki/MR_Peripherals#Scan_Triggers) for 
details, or just ask us for help getting your triggers working.

Please don't hesitate to contact me or just drop by to get help using 
anything. Also let us know right away if something doesn't work as 
expected.

cheers,
bob

-- 
  Robert F. Dougherty, PhD
  Research Director
  Stanford Center for Cognitive&  Neurobiological Imaging
  474 Jordan Hall  *  Stanford CA 94305  *  650-725-0051
  http://www.stanford.edu/~bobd