= MR Scanner (GE 750) =
= MR Scanner (GE 750) =


The CNI scanner is a [https://www2.gehealthcare.com/portal/site/usen/menuitem.e8b305b80b84c1b4d6354a1074c84130/?vgnextoid=9760c555ff930210VgnVCM10000024dd1403RCRD&productid=2760c555ff930210VgnVCM10000024dd1403____ GE Discovery MR750]. It's currently running ESE version 23.1 v02 (the GE operating system). To compile EPIC psd's for the scanner, we have a dedicated server with the necessary software environment installed. Just contact us for details.
We need Adam or Hua to fill in the general properties of this device.  Slew rate, max gradient amplitude, anything else?
 
The CNI scanner is a [https://www.gehealthcare.com/products/goldseal---refurbished-systems/goldseal-magnetic-resonance/discovery-mr750?utm_medium=cpc&utm_source=google&utm_campaign=USC-PS-REG-AlwaysOn&utm_term=&utm_content=12518725892&npclid=Cj0KCQjw_5unBhCMARIsACZyzS22deMIMkJbh6ew8m0rnlAg9oZKQjieLUkTJngTj_7XNIPxSubEMXUaAqUmEALw_wcB&gclid=Cj0KCQjw_5unBhCMARIsACZyzS22deMIMkJbh6ew8m0rnlAg9oZKQjieLUkTJngTj_7XNIPxSubEMXUaAqUmEALw_wcB GE Discovery MR750]. It's currently running ESE version 23.1 v02 (the GE operating system). To compile EPIC psd's for the scanner, we have a dedicated server with the necessary software environment installed. Just contact us for details.


Data were acquired at the Stanford Center for Cognitive and Neurobiological Imaging using a 3T General Electric MR 750 scanner with either a Nova 16- or 32-channel head coil. The Nova 16-channel is similar to the Nova 32-channel coil, but with the front half of the coil removed to allow for an unobstructed field of view. Head motion was minimized by padding around the head.  
Data were acquired at the Stanford Center for Cognitive and Neurobiological Imaging using a 3T General Electric MR 750 scanner with either a Nova 16- or 32-channel head coil. The Nova 16-channel is similar to the Nova 32-channel coil, but with the front half of the coil removed to allow for an unobstructed field of view. Head motion was minimized by padding around the head.  

Revision as of 22:35, 24 August 2023

When the GE OS is upgraded there are certain procedures that must be followed to get certain peripherals working normally. Those procedures are described on the Scanner Upgrade Procedure page.

MR Scanner (UHP)

We need Adam or Hua to fill in the general properties of this device. Slew rate, max gradient amplitude, anything else?

MR Scanner (GE 750)

We need Adam or Hua to fill in the general properties of this device. Slew rate, max gradient amplitude, anything else?

The CNI scanner is a GE Discovery MR750. It's currently running ESE version 23.1 v02 (the GE operating system). To compile EPIC psd's for the scanner, we have a dedicated server with the necessary software environment installed. Just contact us for details.

Data were acquired at the Stanford Center for Cognitive and Neurobiological Imaging using a 3T General Electric MR 750 scanner with either a Nova 16- or 32-channel head coil. The Nova 16-channel is similar to the Nova 32-channel coil, but with the front half of the coil removed to allow for an unobstructed field of view. Head motion was minimized by padding around the head.

Typically, anatomical data are acquired with the 32-channel coil using a 3D Fast SPGR scan (166 sagittal slices, resolution 0.9375 × 0.9375 × 1 mm).

See the Pulse Sequence Pages for parameters of different standard CNI sequences.

Coils

  • Standard GE bird-cage head coil
  • InVivo 8-channel head array (similar to this one)
  • Nova Medical 32-channel head coil (interior coil dimensions - 18.5 cm width, 21 cm length, 24 cm height to nose bridge, 21 cm height to forehead)
  • Nova Medical 16-channel visual array. This is similar to the Nova 32-channel coil, but with the front half removed to allow a completely unobstructed field of view for visual studies. (interior coil dimensions - 18.5 cm width, 21 cm length, 10 cm height)

Extras

  • Tektronix TDS2024B4 channel oscilloscope to debug pulse sequences.
  • Custom foam padding for positioning subjects.

MR Simulator

The CNI has an MR Simulator available for pre-scan training.

Physiological Monitoring

In addition to the respiration and pulse oximetry integrated with the GE scanner, the CNI also has a MedRad Veris for additional physiological measures, such as ECG.